When.com Web Search

  1. Ads

    related to: dc current measurement sensor datasheet pdf file

Search results

  1. Results From The WOW.Com Content Network
  2. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    Fluxgate sensors or saturable inductor current sensors work on the same measurement principle as Hall-effect-based current sensors: the magnetic field created by the primary current to be measured is detected by a specific sensing element. The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect ...

  3. Fiber-optic current sensor - Wikipedia

    en.wikipedia.org/wiki/Fiber-optic_current_sensor

    A fiber-optic current sensor (FOCS) is a device designed to measure direct current. Utilizing a single-ended optical fiber wrapped around the current conductor, [1] FOCS exploits the magneto-optic effect (Faraday effect). [2] The FOCS can measure uni- or bi-directional DC currents up to 600 kA, with an accuracy within ±0.1% of the measured value.

  4. Hall effect sensor - Wikipedia

    en.wikipedia.org/wiki/Hall_effect_sensor

    Hall effect current sensor with internal integrated circuit amplifier. 8 mm opening. Zero current output voltage is midway between the supply voltages that maintain a 4 to 8-volt differential. The non-zero current response is proportional to the voltage supplied and is linear to 60 amperes for this particular (25 A) device.

  5. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    The integrator is lossy, so the Rogowski coil does not have a response down to DC; neither does a conventional current transformer (see Néel effect coils for DC). However, they can measure very slow changing currents with frequency components down to 1 Hz and less. [3] Constant DC current cannot be measured.

  6. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured. Some clamp meters can measure currents of 1000 A and more. Hall effect and vane type clamps can also measure direct current (DC).

  7. Signal conditioning - Wikipedia

    en.wikipedia.org/wiki/Signal_conditioning

    Some sensors require external voltage or current source of excitation, These sensors are called active sensors. (E.g. a temperature sensor like a thermistor & RTD, a pressure sensor (piezo-resistive and capacitive), etc.). The stability and precision of the excitation signal directly relates to the sensor accuracy and stability.

  8. IEEE 1451 - Wikipedia

    en.wikipedia.org/wiki/IEEE_1451

    IEEE 1451 is a set of smart transducer interface standards developed by the Institute of Electrical and Electronics Engineers (IEEE) Instrumentation and Measurement Society's Sensor Technology Technical Committee describing a set of open, common, network-independent communication interfaces for connecting transducers (sensors or actuators) to microprocessors, instrumentation systems, and ...

  9. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...