Search results
Results From The WOW.Com Content Network
In 1961, at a meeting in Scottsdale, Arizona, the Committee on Grade Simplification and Standardization agreed to what is now the current U.S. standard: in part, the dressed size of a 1-inch (nominal) board was fixed at 3 ⁄ 4 inch; while the dressed size of 2 inch (nominal) lumber was reduced from 1 + 5 ⁄ 8 inch to the current 1 + 1 ⁄ 2 ...
The board foot or board-foot is a unit of measurement for the volume of lumber in the United States and Canada [1].It equals the volume of a board that is one foot (30.5 cm) in length, one foot in width, and one inch (2.54 cm) in thickness, or exactly 2.359 737 216 liters.
(*1 often split from larger blanks yielding 2 or 3 actual pieces, thus nominal do not necessarily refer to the unfinished size but based on nomenclature) (*2 "3 inch" widths in 36 and 48 mm appear as both 73 and 68 mm for untreated wood, the 68mm being the most commonly used for indoor partition walls, fitting better together with standard door ...
Steel studs are gaining popularity as a non-combustible alternative, especially for non load-bearing walls, and are required in some firewalls. In New Zealand, the required lumber size and spacing of wall studs are determined using NZS 3604 Timber-framed buildings table 8.2 for loadbearing walls and table 8.4 for non-loadbearing walls. [4]
Light frame material dimensions range from 38 by 89 mm (1.5 by 3.5 in); i.e., a Dimensional number two-by-four to 5 cm by 30 cm (two-by-twelve inches) at the cross-section, and lengths ranging from 2.5 metres (8.2 ft) for walls to 7 metres (23 ft) or more for joists and rafters.
Pipe sizes are documented by a number of standards, including API 5L, ANSI/ASME B36.10M (Table 1) in the US, and BS 1600 and BS 1387 in the United Kingdom. Typically the pipe wall thickness is the controlled variable, and the Inside Diameter (I.D.) is allowed to vary. The pipe wall thickness has a variance of approximately 12.5 percent.
Drywall panels in Canada and the United States are made in widths of 48, 54, and 96 inches (1.2, 1.4, and 2.4 m) and varying lengths to suit the application. The most common width is 48 inches; however, 54-inch-wide panels are becoming more popular as 9-foot (2.7 m) ceiling heights become more common.
Butterfly valve in a large DN-size. Nominal diameter, abbreviated DN (diamètre nominal/Durchmesser nach Norm), is the designation system specified by ISO 6708 for specifying the diameter of trade sizes of metric pipework components, and is the metric equivalent to Nominal Pipe Size. [9]