When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Johnson's parabolic formula - Wikipedia

    en.wikipedia.org/wiki/Johnson's_parabolic_formula

    The slenderness ratio is an indicator of the specimen's resistance to bending and buckling, due to its length and cross section. If the slenderness ratio is less than the critical slenderness ratio, the column is considered to be a short column. In these cases, the Johnson parabola is more applicable than the Euler formula. [5]

  3. McCabe–Thiele method - Wikipedia

    en.wikipedia.org/wiki/McCabe–Thiele_method

    The McCabe–Thiele method is a technique that is commonly employed in the field of chemical engineering to model the separation of two substances by a distillation column. [ 1 ] [ 2 ] [ 3 ] It uses the fact that the composition at each theoretical tray is completely determined by the mole fraction of one of the two components.

  4. Euler's critical load - Wikipedia

    en.wikipedia.org/wiki/Euler's_critical_load

    The cross-section of the column is uniform throughout its length. The direct stress is very small as compared to the bending stress (the material is compressed only within the elastic range of strains). The length of the column is very large as compared to the cross-sectional dimensions of the column. The column fails only by buckling.

  5. Size-exclusion chromatography - Wikipedia

    en.wikipedia.org/wiki/Size-exclusion_chromatography

    Proper column packing is important for maximum resolution: An over-packed column can collapse the pores in the beads, resulting in a loss of resolution. An under-packed column can reduce the relative surface area of the stationary phase accessible to smaller species, resulting in those species spending less time trapped in pores.

  6. Fenske equation - Wikipedia

    en.wikipedia.org/wiki/Fenske_equation

    Fractionation at total reflux. The Fenske equation in continuous fractional distillation is an equation used for calculating the minimum number of theoretical plates required for the separation of a binary feed stream by a fractionation column that is being operated at total reflux (i.e., which means that no overhead product distillate is being withdrawn from the column).

  7. Kovats retention index - Wikipedia

    en.wikipedia.org/wiki/Kovats_retention_index

    If column dimensions Length×diameter×film are divided by 2 and gas velocity is doubled by using H2 in place of Helium, the hold times must be divided by 4 and the ramps must be multiplied by 4 to keep the same index and the same retention temperature for the same compound analyzed. Method translation rules are incorporated in some ...

  8. Column chromatography - Wikipedia

    en.wikipedia.org/wiki/Column_chromatography

    Column chromatography in chemistry is a chromatography method used to isolate a single chemical compound from a mixture. Chromatography is able to separate substances based on differential absorption of compounds to the adsorbent; compounds move through the column at different rates, allowing them to be separated into fractions.

  9. Theoretical plate - Wikipedia

    en.wikipedia.org/wiki/Theoretical_plate

    The calculation process requires the availability of a great deal of vapor–liquid equilibrium data for the components present in the distillation feed, and the calculation procedure is very complex. [2] [3] In an industrial distillation column, the N t required to achieve a given separation also depends upon the amount of reflux used. Using ...