When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    Miniature circuit breaker (MCB)—rated current up to 125 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category. Molded Case Circuit Breaker (MCCB)—rated current up to 1,600 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in higher-rated ...

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.

  4. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    "Switched socket-outlets and connectors with or without interlock" applies to self-contained products that combine within a single enclosure, a socket-outlet or connector according to IEC 60309-1 or IEC 60309-2 and a switching device, with a rated operating voltage not exceeding 1000 VDC or VAC and 500 Hz, and a rated current not exceeding 800 A.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and power receptacle circuits in North American systems are typically radial from a distribution panel containing circuit breakers to protect each branch circuit. [8] The smallest branch circuit rating is 15 amperes, used for general purpose receptacles and lighting.

  6. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  7. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    This saves a homeowner a trip to the breaker panel, should the device trip. Unlike AFCI breakers, AFCI receptacles can be used on any wiring system, regardless of the panel. [citation needed] When installed as the first receptacle on a branch circuit, AFCI receptacles can provide series arc protection for the entire branch circuit. They also ...

  8. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room. In contrast to a simple light switch , which is a single pole, single throw (SPST) switch, multiway switching uses switches with one or more additional contacts and two or more wires are run ...

  9. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    Higher current plugs have more lugs to prevent them from being inserted into a lower current socket outlet, while still allowing them to be inserted into a socket outlet of the same size group rated for a higher current. For example, a 32 A 4-pin plug without neutral can plug into a 50 A 5-pin socket with neutral available.