Ads
related to: residual current device power supply
Search results
Results From The WOW.Com Content Network
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.
Ripple (specifically ripple voltage) in electronics is the residual periodic variation of the DC voltage within a power supply which has been derived from an alternating current (AC) source. This ripple is due to incomplete suppression of the alternating waveform after rectification. Ripple voltage originates as the output of a rectifier or ...
This type of consumer unit was very popular in Britain until 2001 when wiring regulations mandated residual-current device (RCD) protection for sockets that could "reasonably be expected to" supply outdoor equipment (BS 7671:2001, ISBN 0-86341-373-0). There were a number of similar designs from other manufacturers but the Wylex ones are by far ...
To eliminate this confusion, the IEC decided to apply the term residual current device (RCD) to differential-current-operated ELCBs. Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current.
Breakers for protections against earth faults too small to trip an over-current device: Residual-current device (RCD), or residual-current circuit breaker (RCCB) — detects current imbalance, but does not provide over-current protection. In the United States and Canada, these are called ground fault circuit interrupters (GFCI).
This device, which can be a circuit breaker or the first outlet on a circuit, is designed to detect hazardous electrical arcing in the branch circuit wiring as well as in cords and plugs. An AFCI device is designed to trip quickly when it detects potentially dangerous arcing that could start a fire, but not trip with harmless arcing as part of ...
Power system protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults [citation needed] through the disconnection of faulted parts from the rest of the electrical network. The objective of a protection scheme is to keep the power system stable by isolating only the components ...
The second problem, the inadequacy of fuses to act as the sole safety device in most power systems, is probably best resolved by the use of residual-current devices (RCDs). In any properly functioning electrical appliance, the current flowing into the appliance on the active line should equal the current flowing out of the appliance on the ...