Results From The WOW.Com Content Network
For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...
With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...
Standard cubic feet per minute (SCFM) is a volumetric flow-rate corrected to a set of "standardized" conditions of pressure, temperature, and relative humidity. The standard conditions are often defined as 14.7 psia, temperature 70°F and relative humidity 0%, but the conditions may vary depending on the "standard" used.
Pollution regulations in the United States typically reference their pollutant limits to an ambient temperature of 20 to 25 °C as noted above. In most other nations, the reference ambient temperature for pollutant limits may be 0 °C or other values. 1 percent by volume = 10,000 ppmv (i.e., parts per million by volume).
It is possible to envision three-dimensional (3D) graphs showing three thermodynamic quantities. [12] [13] For example, for a single component, a 3D Cartesian coordinate type graph can show temperature (T) on one axis, pressure (p) on a second axis, and specific volume (v) on a third. Such a 3D graph is sometimes called a p–v–T diagram. The ...
Since 1982, STP has been defined as a temperature of 273.15 K (0 °C, 32 °F) and an absolute pressure of exactly 1 bar (100 kPa, 10 5 Pa). NIST uses a temperature of 20 °C (293.15 K, 68 °F) and an absolute pressure of 1 atm (14.696 psi, 101.325 kPa). [3] This standard is also called normal temperature and pressure (abbreviated as NTP).
PSI-Plot provides various 2D and 3D plot types and allows users to customize the graphics in great detail for visual presentations and for submission to research journals for publication. Users have full control of plot and label attributes, including background color, color gradients, size, and thickness.
21 MPa 3,000 psi Ballistic pressure exerted as high-power bullet strikes a solid bulletproof object [citation needed] 22 MPa 3,200 psi Critical pressure of water 28 MPa 4,100 psi Overpressure caused by the bomb explosion during the Oklahoma City bombing [72] 40 MPa 5,800 psi Water pressure at the depth of the wreck of the Titanic: 69 MPa 10,000 psi