Results From The WOW.Com Content Network
Mass spectrometry data analysis is specific to the type of experiment producing the data. General subdivisions of data are fundamental to understanding any data. Many mass spectrometers work in either negative ion mode or positive ion mode. It is very important to know whether the observed ions are negatively or positively charged.
The mass/charge ratios of these secondary ions are measured with a mass spectrometer to determine the elemental, isotopic, or molecular composition of the surface to a depth of 1 to 2 nm. In a liquid metal ion source (LMIS), a metal (typically gallium ) is heated to the liquid state and provided at the end of a capillary or a needle.
A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass spectrometer. Not all mass spectra of a given substance are the same; for example, some mass spectrometers break the analyte molecules into fragments ; others observe the intact molecular ...
In the selected ion flow tube mass spectrometer, SIFT-MS, ions are generated in a microwave plasma ion source, usually from a mixture of laboratory air and water vapor. . From the formed plasma, a single ionic species is selected using a quadrupole mass filter to act as "precursor ions" (also frequently referred to as primary or reagent ions in SIFT-MS and other processes involving chemical ...
Peroxynitrate chemical ionization mass spectrometer at the US National Oceanic and Atmospheric Administration. CI mass spectrometry is a useful tool in structure elucidation of organic compounds. [3] This is possible with CI, because formation of [M+1] + eliminates a stable molecule, which can be used to guess the functional groups present. [3]
The mass spectrometry analysis, however, takes place at high vacuum condition. Therefore, ions entering the mass spectrometer, first go through a source - to - analyzer interface (vacuum interface), which was designed in order to bridge the atmospheric pressure region to the mass spectrometer vacuum. It also minimizes spectrometer contamination.
Schematic of field desorption ionization with emitter at left and mass spectrometer at right. Field desorption (FD) is a method of ion formation used in mass spectrometry (MS) in which a high-potential electric field is applied to an emitter with a sharp surface, such as a razor blade, or more commonly, a filament from which tiny "whiskers" have formed.
A constant current of 2–5 microamps is maintained from the corona needle. Sample ions are produced by ion-molecule reactions (as described below), and pass through a small orifice or tube into the ion transfer region leading to the mass spectrometer. Various geometries of ion source are possible, depending on application.