When.com Web Search

  1. Ads

    related to: how to install a backflow barrier in basement door

Search results

  1. Results From The WOW.Com Content Network
  2. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  3. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    AVBs must be installed a minimum of 6 inches above the highest usage point in the system (i.e. sprinkler, drip emitter, etc.) Underground installation of AVBs is entirely ineffectual in providing backflow protection as groundwater in the underground vault could be drawn into the water system, contaminating it.

  4. Pressure vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Pressure_vacuum_breaker

    A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet. This makes it acceptable for applications that are high hazard or where valves are ...

  5. Basement waterproofing - Wikipedia

    en.wikipedia.org/wiki/Basement_waterproofing

    The drainage system collects any water entering the basement and drains it to an internally placed sump pump system, which will then pump the water out of the basement. The Federal Emergency Management Agency (FEMA) recommends basement waterproofing with a water alarm and "battery-operated backup pump" as a preventive measure against the high ...

  6. Vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Vacuum_breaker

    A vacuum breaker is a device that prevents water from being siphoned backward in a direction it is not desired to go. They are commonly placed on a bibcock valve or toilet or urinal flush valve, in which application they can prevent hose or drainage water from back-siphoning into the public drinking water system.

  7. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    A double check valve or double check assembly (DCA) is a backflow prevention device designed to protect water supplies from contamination. [1] It is different from the two-way check valves (sometimes erroneously referred to as double check valves) used in air brake systems on heavy trucks which select from the highest pressure source.

  8. Backwater valve - Wikipedia

    en.wikipedia.org/wiki/Backwater_valve

    A backwater valve is a backflow prevention device used to prevent outbound water through a dwelling's drain pipes from re-entering -- "back flowing"—into a home. The valve contains a flap that allows water to exit the home, but closes to prevent the back flow into the home.

  9. WELL Building Standard - Wikipedia

    en.wikipedia.org/wiki/WELL_Building_Standard

    Label or manual at point-of-connection to shut-off pipe and all water treatment devices need backflow prevention system such as air gap or backflow preventer valve. The last 1 point is to manage moisture by scheduling inspection, notification system in the building and to submit all inspection result to WELL annually.