When.com Web Search

  1. Ads

    related to: 30 amp 240v disconnect switch for refrigerator with 2 wire

Search results

  1. Results From The WOW.Com Content Network
  2. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    As an example, the 5-15R is the common 125 V two-pole, three-wire receptacle rated for 15 A. The L5-15R, while sharing the same electrical rating, is a locking design that is not physically compatible with the straight-blade 5-15 design. The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A. Although ...

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. AS/NZS 3112 - Wikipedia

    en.wikipedia.org/wiki/AS/NZS_3112

    The shank of the active and neutral pins of every 10 amp and 15 amp flat-pin plug sold after 3 April 2005 are required to be insulated, in accordance with AS/NZS 3112:2000. [ 1 ] Since 2000, the nominal voltage in most areas of Australia has been 230 V, [ 2 ] [ 3 ] [ 4 ] except for Western Australia, which remains at 240 V, and Queensland ...

  5. IEC 60309 - Wikipedia

    en.wikipedia.org/wiki/IEC_60309

    The standard includes preferred current ratings and wire gauges for both International (deemed Series I) and North American (deemed Series II) applications. Series I preferred current ratings (in amps) are: 16, 32, 63, 125, 250, 400, 630 and 800, with wire gauges specified as mm 2 .

  6. Disconnector - Wikipedia

    en.wikipedia.org/wiki/Disconnector

    Where it is adopted the earthing switch must be used and the performance must be increased by the typical value. The open-air disconnecting switches typically need maintenance every five years (every two years under very polluted conditions), while circuit breakers have maintenance intervals of 15 years. [2]

  7. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    In building wiring, multiway switching is the interconnection of two or more electrical switches to control an electrical load from more than one location.A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room.

  8. Electrical connector - Wikipedia

    en.wikipedia.org/wiki/Electrical_connector

    PCB mount connectors soldered to a printed circuit board, providing a point for cable or wire attachment. [6]: 56 (e.g. pin headers, screw terminals, board-to-board connectors) Splice or butt connectors (primarily insulation displacement connectors) that permanently join two lengths of wire or cable

  9. Appliance classes - Wikipedia

    en.wikipedia.org/wiki/Appliance_classes

    Green ground wire with yellow stripe Symbol used to mark the Protective Earthing Conductor terminal of Class I equipment. Appliance class I is not only based on the basic insulation, but the casing and other conductive parts are also connected with a low-resistant earth conductor.