The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
An example of a Levey–Jennings chart with upper and lower limits of one and two times the standard deviation. A Levey–Jennings chart is a graph that quality control data is plotted on to give a visual indication whether a laboratory test is working well.
A check should first be done to ensure that the data should be seen is precise and accurate. Next, systematic daily checks such as analysing blanks, calibration standards, quality control check samples, and references must be performed to establish the reproducibility of the data.
Reference materials are particularly important for analytical chemistry and clinical analysis. [2] Since most analytical instrumentation is comparative, it requires a sample of known composition (reference material) for accurate calibration.
Calibration involves taking three readings: one with an empty tube R 0, one with a tube filled with the calibration reference material, and one with the tube filled with the sample R s. Some balances feature an auto-tare function that eliminates the need for the R 0 measurement. [11] The first two readings provide a calibration constant (C).
Calibration is needed because the glass electrode does not give reproducible electrostatic potentials over longer periods of time. [13]: 238–239 Consistent with principles of good laboratory practice, calibration is performed with at least two standard buffer solutions that span the range of pH values to be measured. For general purposes ...
The calibration curve that does not use the internal standard method ignores the uncertainty between measurements. The coefficient of determination (R 2 ) for this plot is 0.9985. In the calibration curve that uses the internal standard, the y-axis is the ratio of the nickel signal to the yttrium signal.