Lightning protection systems are designed to mitigate the effects of lightning through connection to extensive grounding systems that provide a large surface area connection to earth. The large area is required to dissipate the high current of a lightning strike without damaging the system conductors by excess heat.
Lightning and Earthing protection systems are essential for the protection of humans, structures, protecting buildings from mechanical destruction caused by lightning effects and the associated risk of fire, Transmission lines, and electrical equipment from electric shock and Overcurrent.
But this does not change the need for adequate conductor size to any given piece of equipment in case of a fault. Lightning protection is provided by bonding the multipoint ground grid to one or more grounding rods under or at the perimeter of the building, and then up to the lightning rods. If the building has significant metal framing ...
Grounding connectors. Connectors for earthing installation are a means of communication between the various components of the earthing and lightning protection installations (earthing rods, earthing conductors, current leads, busbars, etc.). For high voltage installations, exothermic welding is used for underground connections.
The halo is connected to the main building ground, which may include an underground ring ground outside the building, with vertical conductors especially in the corners of the building. Electrical equipment is also often placed in fully enclosed metal cabinets, which function as Faraday cages to further protect the equipment. The halo may be ...
IEC 60834 Tele-protection equipment of power systems – Performance and testing; IEC 60835 Methods of measurement for equipment used in digital microwave radio transmission systems; IEC 60836 Specifications for unused silicone insulating liquids for electrotechnical purposes; IEC 60838 Miscellaneous lampholders
Unlike ATEX which uses numbers to define the safety "Category" of equipment (namely 1, 2, and 3), the IEC continued to utilise the method used for defining the safe levels of intrinsic safety namely "a" for zone 0, "b" for zone 1 and "c" for zone 2 and apply this Equipment Level of Protection to all equipment for use in hazardous areas since ...
The primary reason for the use of isolated grounds (IG) is to provide a noise-free ground return, separate from the equipment grounding (EG) return. The EG circuit includes all of the metal conduit, outlet boxes, and metal enclosures that contain the wiring and must be grounded to provide a safe return path in case of fault currents.