When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Boiler feedwater - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater

    The treatment of boiler water can be put into two parts. These are internal treatment and external treatment. (Sendelbach, p. 131) [4] The internal treatment is for boiler feed water and external treatment is for make-up feed water and the condensate part of the system. Internal treatment protects against feed water hardness by preventing ...

  3. Boiler feedwater pump - Wikipedia

    en.wikipedia.org/wiki/Boiler_feedwater_pump

    The water may be freshly supplied or returning condensate produced as a result of the condensation of the steam produced by the boiler. These pumps are normally high pressure units that take suction from a condensate return system and can be of the centrifugal pump type or positive displacement type.

  4. Feedwater heater - Wikipedia

    en.wikipedia.org/wiki/Feedwater_heater

    A feedwater heater is a power plant component used to pre-heat water delivered to a steam generating boiler. [1] [2] [3] Preheating the feedwater reduces the irreversibilities involved in steam generation and therefore improves the thermodynamic efficiency of the system. [4]

  5. Deaerator - Wikipedia

    en.wikipedia.org/wiki/Deaerator

    The deaerator is part of the feedwater heating system. [1] [2] Dissolved oxygen in feedwater will cause serious corrosion damage in a boiler by attaching to the walls of metal piping and other equipment forming oxides (like rust). Dissolved carbon dioxide combines with water to form carbonic acid that may cause further

  6. Thermal power station - Wikipedia

    en.wikipedia.org/wiki/Thermal_power_station

    The makeup water in a 500 MWe plant amounts to perhaps 120 US gallons per minute (7.6 L/s) to replace water drawn off from the boiler drums for water purity management, and to also offset the small losses from steam leaks in the system. The feed water cycle begins with condensate water being pumped out of the condenser after traveling through ...

  7. Forced circulation boiler - Wikipedia

    en.wikipedia.org/wiki/Forced_circulation_boiler

    In a water tube boiler, the water is recirculated inside until the vapor pressure of the water overcomes the vapor pressure inside the stream drum and becomes saturated steam. The forced circulation boiler begins the same as a natural circulation boiler, at the feed water pump. Water is introduced into the steam drum and is circulated around ...

  8. Boiler design - Wikipedia

    en.wikipedia.org/wiki/Boiler_design

    Sections of a steam locomotive showing the many fire-tubes which carry the hot gases of the fire through the boiler to heat the water and so create steam. Boiler design is the process of designing boilers used for various purposes. The main function of a boiler is to heat water to generate steam. Steam produced in a boiler can be used for a ...

  9. Boiler - Wikipedia

    en.wikipedia.org/wiki/Boiler

    Diagram of a water-tube boiler. Water-tube boiler In this type, tubes filled with water are arranged inside a furnace in a number of possible configurations. Often the water tubes connect large drums, the lower ones containing water and the upper ones steam and water; in other cases, such as a mono-tube boiler, water is circulated by a pump ...