Search results
Results From The WOW.Com Content Network
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...
Overhead power lines are easiest to diagnose since the problem is usually obvious, e.g., a tree has fallen across the line, or a utility pole is broken and the conductors are lying on the ground. Locating faults in a cable system can be done either with the circuit de-energized, or in some cases, with the circuit under power.
At two multiples of the rated current, the recloser's rapid trip curve can cause a trip (off circuit) in as little as 1.5 cycles (or 30 milliseconds). During those 1.5 cycles, other separate circuits can see voltage dips or blinks until the affected circuit opens to stop the fault current.
A kick will occur when the bottom hole pressure(BHP) of a well falls below the formation pressure and the formation fluid flows into the wellbore. There are usually causes for kicks some of which are: Failure to keep the hole full during a trip; Swabbing while tripping; Lost circulation; Insufficient density of fluid; Abnormal pressure
A shunt-trip unit appears similar to a normal breaker and the moving actuators are ganged to a normal breaker mechanism to operate together in a similar way, but the shunt trip is a solenoid intended to be operated by an external constant-voltage signal, rather than a current, commonly the local mains voltage or DC. These are often used to cut ...
At 25A it might trip as quickly as half a sec, but might take up to about a half min. And we should specifically mention "nuisance tripping", and explain that motors have short-term peak surge currents when they start, so circuit breakers are designed to not trip too quickly. -96.233.19.191 16:39, 11 July 2014 (UTC)
An automatic trip is an action performed by some system, usually a safety instrumented system, programmable logic controller, or distributed control system, to put an industrial process into a safe state. It is triggered by some parameter going into a pre-determined unsafe state.
Another cause of nuisance tripping is due to accumulated or burden currents caused by items with lowered insulation resistance. This may occur due to older equipment, or equipment with heating elements, or even wiring in buildings in the tropics where prolonged damp and rain conditions can cause the insulation resistance to lower due to ...