  2. Chromatography column - Wikipedia

    en.wikipedia.org/wiki/Chromatography_column

    To prevent the stationary phase from leaking out of the column interior a polymer, stainless steel or ceramic net is usually applied. Depending on the application material- and size-requirements may change. Gas chromatography (GC): Older columns were made of glass or metal packed with particles of a solid stationary phase. More recently ...

  3. Gas chromatography - Wikipedia

    en.wikipedia.org/wiki/Gas_chromatography

    The stationary phase is contained inside of a separation column. Today, most GC columns are fused silica capillaries with an inner diameter of 100–320 micrometres (0.0039–0.0126 in) and a length of 5–60 metres (16–197 ft). The GC column is located inside an oven where the temperature of the gas can be controlled and the effluent coming ...

  4. Chromatography - Wikipedia

    en.wikipedia.org/wiki/Chromatography

    Stainless steel and glass are the usual materials for packed columns and quartz or fused silica for capillary columns. Gas chromatography is based on a partition equilibrium of analyte between a solid or viscous liquid stationary phase (often a liquid silicone-based material) and a mobile gas (most often helium). The stationary phase is adhered ...

  5. Van Deemter equation - Wikipedia

    en.wikipedia.org/wiki/Van_Deemter_equation

    For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column. Alternatively, the linear velocity can be taken as the ratio of the column length to the dead time. If the mobile phase is a gas, then the pressure correction must be applied.

  6. Column chromatography - Wikipedia

    en.wikipedia.org/wiki/Column_chromatography

    The particle size of the stationary phase is generally finer in flash column chromatography than in gravity column chromatography. For example, one of the most widely used silica gel grades in the former technique is mesh 230 – 400 (40 – 63 μm), while the latter technique typically requires mesh 70 – 230 (63 – 200 μm) silica gel.

  7. Monolithic HPLC column - Wikipedia

    en.wikipedia.org/wiki/Monolithic_HPLC_column

    The basic methods of separation in HPLC rely on a mobile phase (water, organic solvents, etc.) being passed through a stationary phase (particulate silica packings, monoliths, etc.) in a closed environment (column); the differences in reactivity among the solvent of interest and the mobile and stationary phases distinguish compounds from one ...

  8. Kovats retention index - Wikipedia

    en.wikipedia.org/wiki/Kovats_retention_index

    Capillary inner diameter is well defined but film thickness reduces by bleed and thermal breakdown that occur after column heating over time, depending on chemical bonding to the silica glass wall and polymer cross-linking of the stationary phase.

  9. Elution - Wikipedia

    en.wikipedia.org/wiki/Elution

    Elution principle of column chromatography. In analytical and organic chemistry, elution is the process of extracting one material from another by washing with a solvent: washing of loaded ion-exchange resins to remove captured ions, or eluting proteins or other biopolymers from a gel electrophoresis or chromatography column.