When.com Web Search

  1. Ad

    related to: breaker size for transformer table and bench

Search results

  1. Results From The WOW.Com Content Network
  2. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Types used in commercial and industrial low-voltage distribution systems are rated to safely interrupt 200,000 amperes. The rating of power circuit breakers varies according to the application voltage; a circuit breaker that interrupts 50,000 amperes at 208 volts might be rated to interrupt only 10,000 amperes at 600 volts, for example.

  3. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Circuit breakers with higher ratings can have adjustable trip settings, allowing fewer standardized products to be used, adjusted to the applicable precise ratings when installed. For example, a circuit breaker with a 400 ampere frame size might have its over-current detection threshold set only 300 amperes where that rating is appropriate.

  5. Ring main unit - Wikipedia

    en.wikipedia.org/wiki/Ring_main_unit

    It includes in one unit two switches that can connect the load to either or both main conductors, and a fusible switch or circuit breaker and switch that feed a distribution transformer. [1] The metal enclosed unit connects to the transformer either through a bus throat of standardized dimensions, or else through cables and is usually installed ...

  6. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    Control of solid state loads with transformer isolation: 60947-5-1 AC-14: Control of small electromagnetic loads: 60947-5-1 AC-15: Control of A.C. electromagnetic loads: 60947-5-1 AC-20: Connecting and disconnecting under no-load conditions: 60947-3 AC-21: Switching of resistive loads, including moderate overloads: 60947-3 AC-22

  7. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design.

  8. Power supply - Wikipedia

    en.wikipedia.org/wiki/Power_supply

    A circuit breaker contains an element that heats, bends and triggers a spring which shuts the circuit down. Once the element cools, and the problem is identified the breaker can be reset and the power restored. Some power supplies use a thermal cutout buried in the transformer rather than a fuse. The advantage is it briefly allows greater ...

  9. Electrical wiring in the United Kingdom - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_the...

    Conductor size and voltage drop tables are available to determine the selection, which will be based on the load current supplied and factors such as building insulation. The choice of circuit breaker is also based on the normal rated current of the circuit. Modern circuit breakers have overload and short circuit current protection combined.