  2. Dark-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Dark-field_microscopy

    The interpretation of dark-field images must be done with great care, as common dark features of bright-field microscopy images may be invisible, and vice versa. In general the dark-field image lacks the low spatial frequencies associated with the bright-field image, making the image a high-passed version of the underlying structure.

  3. Bright-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Bright-field_microscopy

    Bright-field microscopy (BF) is the simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light , and contrast in the sample is caused by attenuation of the transmitted light in dense areas of the sample.

  4. Scanning transmission electron microscopy - Wikipedia

    en.wikipedia.org/wiki/Scanning_transmission...

    Axial bright-field detectors are located in the centre of the cone of illumination of the transmitted beam, and are often used to provide complementary images to those obtained by ADF imaging. [12] Annular bright-field detectors, located within the cone of illumination of the transmitted beam, have been used to obtain atomic resolution images ...

  5. 4D scanning transmission electron microscopy - Wikipedia

    en.wikipedia.org/wiki/4D_scanning_transmission...

    An annular dark-field image taken may be complementary to a bright-field image constructed from the captured CBED images. The use of a hollow detector with a hole in the middle can allow for transmitted electrons to be passed to an EELS detector while scanning. This allows for the simultaneous collection of chemical spectra information and ...

  6. Annular dark-field imaging - Wikipedia

    en.wikipedia.org/wiki/Annular_dark-field_imaging

    In contrast, STEM dark-field imaging does not use an aperture to differentiate the scattered electrons from the main beam, but uses an annular detector to collect only the scattered electrons. [2] Consequently, the contrast mechanisms are different between conventional dark field imaging and the STEM dark field.

  7. Weak-beam dark-field microscopy - Wikipedia

    en.wikipedia.org/wiki/Weak-beam_dark-field...

    Follow the Kikuchi lines to form the two-beam condition that is orienting the sample in bright field mode such that g is excited and is close to 0. Align the sample as if a dark field image were to be taken such that 1g aligns with the optical axis. Further tilt the sample to excite ng. The most common condition is g-3g.

  8. Brightland vs. Graza: Which Popular Olive Oil Is Right for You?

    www.aol.com/brightland-vs-graza-popular-olive...

    Taryn Pire. TOTAL: 97/100 Graza’s angle seems to be exposing the olive oil industry for selling rancid, old oil while also promoting their own high-quality, single-source oil that’s designed ...

  9. Phase-contrast microscopy - Wikipedia

    en.wikipedia.org/wiki/Phase-contrast_microscopy

    The same cells imaged with traditional bright-field microscopy (left), and with phase-contrast microscopy (right) Phase-contrast microscopy is particularly important in biology. It reveals many cellular structures that are invisible with a bright-field microscope, as exemplified in the figure.