Search results
Results From The WOW.Com Content Network
Beam and block is a construction method to support flooring, especially for ground floors as well as multi story buildings. [1] It is made of cast concrete , one piece of which is a prestressed concrete beam , which can be an inverted T-shaped beam, or lintel, the other piece being a simple rectangular block. [ 1 ]
The waffle slab floor system has several advantages: Better for buildings that require less vibrations – this is managed by the two way joist reinforcements that form the grid. Bigger spans can be achieved with less material, being more economical and environmentally friendly; Some people find the waffle pattern aesthetically pleasing [4]
A common type of insulated slab is the beam and block system (mentioned above) which is modified by replacing concrete blocks with expanded polystyrene blocks. [11] This not only allows for better insulation but decreases the weight of slab which has a positive effect on load bearing walls and foundations. Formwork set for concrete pour.
A compressed earth block (CEB), also known as a pressed earth block or a compressed soil block, is a building material made primarily from an appropriate mix of fairly dry inorganic subsoil, non-expansive clay, sand, and aggregate. Forming compressed earth blocks requires dampening, mechanically pressing at high pressure, and then drying the ...
An alternative is to put a strip of rubber underneath the floor slabs. Hollow-core slabs and wall elements without prestressed steel wire can be formed by extruders. The size of these elements will typically range in width from 600 to 2400 mm, in thickness from 150 to 500 mm, and can be delivered in lengths of up to 24 m.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The herringbone pattern is an arrangement of rectangles used for floor tilings and road pavement, so named for a fancied resemblance to the bones of a fish such as a herring. The blocks can be rectangles or parallelograms. The block edge length ratios are usually 2:1, and sometimes 3:1, but need not be even ratios.
In terms of the actual load on a structure, there is no difference between dead or live loading, but the split occurs for use in safety calculations or ease of analysis on complex models. To meet the requirement that design strength be higher than maximum loads, building codes prescribe that, for structural design, loads are increased by load ...