The 5-30R has the same two-pole, three-wire configuration and 125 V rating, but is rated for 30 A. ... NEMA Receptacle chart (non-twist lock) [2] V NE MA 15 A (12) 20 ...
Industrial devices may also be constructed to be dust or water-tight. NEMA wiring devices are made in current ratings from 15–60 A, and voltage ratings from 125–600 V. There are two basic configurations of NEMA plug and socket: straight-blade and locking. Numbers prefixed by L are twist-lock, others are straight blade. Locking type ...
IEC 60309 (formerly IEC 309 and CEE 17, also published by CENELEC as EN 60309) is a series of international standards from the International Electrotechnical Commission (IEC) for "plugs, socket-outlets and couplers for industrial purposes".
Added common uses of EV and RV to NEMA 14-50, and air conditioner (A/C) to NEMA 6-15: 18:21, 20 April 2020: 765 × 756 (44 KB) Olawlor: Saved as "Plain SVG" to avoid Inkscape SVG namespace errors in previous version. 00:00, 17 February 2019: 765 × 756 (46 KB) Olawlor: Ground pins are all shown in the up direction.
The devices are named using the format NEMA n-mmX, where n is an identifier for the configuration of pins and blades, mm is the maximum current rating, and X is either P for plug or R for receptacle. For example, NEMA 5-15R is a configuration type 5 receptacle supporting 15 A. Corresponding P and R versions are designed to be mated. Within the ...
NEMA contact ratings are how much current at a rated voltage a relay or other pilot device can switch. The current rating of smaller NEMA contactors or their auxiliaries are defined by NEMA ICS 5: Industrial Control and Systems, Control Circuit and Pilot Devices [1] standard. The nomenclature is a letter followed by a three-digit number, the ...
Below is a list of NEMA enclosure types; these types are further defined in NEMA 250- Enclosures for Electrical Equipment. Each type specifies characteristics of an enclosure, but not, for example, a specific enclosure size. Note that higher numbers do not include the lower-numbered tests. For example, types 3, 4 and 6 are intended for outdoor ...
In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...