Search results
Results From The WOW.Com Content Network
Steady-state free precession: SSFP: Maintenance of a steady, residual transverse magnetisation over successive cycles. [7] Creation of cardiac MRI videos (pictured). [7] Effective T2 or "T2-star" T2* Spoiled gradient recalled echo (GRE) with a long echo time and small flip angle [8] Low signal from hemosiderin deposits (pictured) and ...
Magnetic resonance myelography (MR myelography or MRI myelography) is a noninvasive medical imaging technique that can provide anatomic information about the subarachnoid space. It is a type of MRI examination that uses a contrast medium and magnetic resonance imaging scanner to detect pathology of the spinal cord , including the location of a ...
Arterial spin labeling (ASL), also known as arterial spin tagging, is a magnetic resonance imaging technique used to quantify cerebral blood perfusion by labelling blood water as it flows throughout the brain. ASL specifically refers to magnetic labeling of arterial blood below or in the imaging slab, without the need of gadolinium contrast. [1]
An MRI pulse sequence in magnetic resonance imaging (MRI) is a particular setting of pulse sequences and pulsed field gradients, resulting in a particular image appearance. [ 1 ] A multiparametric MRI is a combination of two or more sequences, and/or including other specialized MRI configurations such as spectroscopy .
Nowadays, MRI has all but replaced myelography. [4] MRI is preferable because injection of contrast medium into the spinal canal is infrequently needed for better images. However, a CT myelogram may be useful for patients who cannot undergo MRI (e.g., those with pacemakers or cochlear implants). CT is preferred when MRI images are limited by ...
Functional magnetic resonance imaging (fMRI) of the spinal cord (spinal fMRI) is an adaptation of the fMRI method that has been developed for use in the brain. Although the basic principles underlying the methods are the same, spinal fMRI requires a number of specific adaptations to accommodate the periodic motion of the spinal cord, the small cross-sectional dimensions (roughly 8 mm × 15 mm ...
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The key to Phase-contrast MRI (PC-MRI) is the use of a bipolar gradient. [4] A bipolar gradient has equal positive and negative magnitudes that are applied for the same time duration. The bipolar gradient in PC-MRI is put in a sequence after RF excitation but before data collection during the echo time of the generic MRI modality.