The fire requirements on riser cable are not as strict. Thus, plenum cable can always replace riser cable, but riser cable cannot replace plenum cable in plenum spaces. Both plenum and riser cables commonly include a rope or polymer filament with high tensile strength, which helps support the weight of the cable when it is dangling in an open ...
The NEC is developed by NFPA's Committee on the National Electrical Code, which consists of twenty code-making panels and a technical correlating committee. Work on the NEC is sponsored by the National Fire Protection Association. The NEC is approved as an American national standard by the American National Standards Institute (ANSI). It is ...
A non-plenum airspace can become a plenum airspace by accident if the ductwork is disconnected and not properly repaired and resealed. Ductwork disconnection can occur due to building damage such as earthquakes, aging, or adverse environment causing the metal to corrode and fall apart, or simply negligence on the part of building contractors ...
Not all US jurisdictions permit use of non-metallic sheathed cable. The NEC does not permit use of NM cable in large, fire-resistant, or high-rise structures. [10] In type NM cable, conductor insulation is color-coded for identification, typically one black, one white, and a bare grounding conductor.
Optical fiber, nonconductive, riser (OFNR) is a type of optical fiber cable.As designated by the National Fire Protection Association (NFPA), this name is used for interior fiber-optic cables which contain no electrically conductive components, and which are certified for use in riser applications; they are engineered to prevent the spread of fire from floor to floor in a building.
The NEC Zone system was created to harmonize with IEC classification system, and therefore reduce the complexity of management. Canada has a similar system with CSA Group standard C22.1, the Canadian Electrical Code , which defines area classification and installation principles.
Telecommunications power cable, as described in Telcordia GR-347 & GR-347, [1] consist of a stranded copper conductor used in AC/DC circuits up to 600 V that are insulated with non-halogen, limited smoke, polyolefin materials that are heat-resistant, moisture-resistant, and flame-retardant. These cables are provided as either Class B (standard ...
A cable terminated according to T568A on one end and T568B on the other is a crossover cable when used with the earlier twisted-pair Ethernet standards that use only two of the pairs because the pairs used happen to be pairs 2 and 3, the same pairs on which T568A and T568B differ. Crossover cables are occasionally needed for 10BASE-T and ...