  1. Results From The WOW.Com Content Network
  2. Dissolved gas analysis - Wikipedia

    en.wikipedia.org/wiki/Dissolved_gas_analysis

    Dissolved gas analysis (DGA) is an examination of electrical transformer oil contaminants. [1] Insulating materials within electrical equipment liberate gases as they slowly break down over time. The composition and distribution of these dissolved gases are indicators of the effects of deterioration, such as pyrolysis or partial discharge , and ...

  3. Transformer oil testing - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil_testing

    The lower the resulting breakdown voltage, the poorer the quality of the transformer oil. The transformer oil is filled in the vessel of the testing device. Two standard-compliant test electrodes with a typical clearance of 2.5 mm are surrounded by the dielectric oil. A test voltage is applied to the electrodes and is continuously increased up ...

  4. Transformer oil - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil

    Transformer oil or insulating oil is an oil that is stable at high temperatures and has excellent electrical insulating properties. It is used in oil-filled wet transformers, [ 1 ] some types of high-voltage capacitors , fluorescent lamp ballasts , and some types of high-voltage switches and circuit breakers.

  5. Kelman Ltd. - Wikipedia

    en.wikipedia.org/wiki/Kelman_Ltd.

    Early in 2003 Kelman moved into the area of Dissolved Gas Analysis (DGA), which is the essential test for condition monitoring of electrical transformers. Kelman produced both portable and on-line DGA equipment, which are currently in use by many utility companies.

  6. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    Thermal modelling – The useful life of a transformer is partially determined by the ability of the transformer to dissipate its internally generated heat to its surroundings. [3] The comparison of actual and predicted operating temperatures can provide a sensitive diagnosis of the transformer condition and might indicate abnormal operation.

  7. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60055 Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) IEC 60059 IEC standard current ratings; IEC 60060 High-voltage test techniques; IEC 60061 Lamp caps and holders together with gauges for the control of interchangeability and safety