Search results

  1. Results From The WOW.Com Content Network
  2. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law between the airflow rate and the pressure difference across the building envelope as follows: [16] q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in m 3 h −1; C L is the air leakage coefficient expressed in m 3 h −1 Pa −n

  3. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Leakage area estimates can also be normalized for the size of the enclosure being tested, For example, the LEED Green Building Rating System has set an airtightness standard for multi-family dwelling units of 1.25 square inches (8.1 cm 2) of leakage area per 100 square feet (9.3 m 2) of enclosure area, to control tobacco smoke between units.

  4. National Fenestration Rating Council - Wikipedia

    en.wikipedia.org/wiki/National_Fenestration...

    NFRC labels provide performance ratings for such products in five categories: U-value, Solar Heat Gain Coefficient, Visible Transmittance, Air Leakage, and Condensation Resistance. [1] This allows architects, builders, code officials, contractors, home owners, and specifiers to compare the energy efficiency among products, and determine whether ...

  5. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    A basic duct leakage testing system includes three components: a calibrated fan, a register sealing system, and a device to measure fan flow and building pressure. Supply registers or return air grills are sealed using adhesive tapes, cardboard, or non-adhesive reusable seals.

  6. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  7. House Energy Rating - Wikipedia

    en.wikipedia.org/wiki/House_energy_rating

    In Ireland, the building energy ratings are in existence since 2007. In this country Building Energy Rating (BER) is used as EPC. The scheme was mandatory for new dwelling and in 2008, its use was extended to non-residential and public buildings, in 2009 the HERS cover the all types of buildings. BER is a calculation based HERS.

  8. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    Infiltration is the unintentional or accidental introduction of outside air into a building, typically through cracks in the building envelope and through use of doors for passage. [1] Infiltration is sometimes called air leakage. The leakage of room air out of a building, intentionally or not, is called exfiltration.

  9. Facility condition index - Wikipedia

    en.wikipedia.org/wiki/Facility_Condition_Index

    The American Public Works Association publication, Special Report #62, describes the use and value of facility condition rating systems in Chapter 3.6. Within the US Federal Government, the "condition index" (CI) is a general measure of the constructed asset's condition at a specific point in time. [ 2 ]