Results From The WOW.Com Content Network
If the MI cable jacket has been damaged, the magnesium oxide will wick moisture into the cable, and it will lose its insulating properties, causing shorts to the copper cladding and thence to earth. It is often necessary to remove 0.5 to 2 metres (1.6 to 6.6 ft) of the MI cable and splice in a new section to accomplish the repair.
The 1915 textbook Practical Electric Wiring describes the construction of the Western Union splice; short tie and long tie. The short tie splice has it being formed after stripping the insulation from a pair of wires for several inches, each, crossing the wires left over right as shown in figure part A; then, a hooked cross (figure part B) is formed holding the crossing point of the two wires ...
The content could be general descriptive information, information on wiring and connections, test procedures, or piece-part replacement and repair information. The BSP documents were produced in primarily two formats, 8 1/2"x11" pages for use in office environments, and in a small, portable format (4" x 6 7/8") for use by installers on the job ...
Splice site of a copper wire. Cable sleeve (lead sleeve) for connecting paper-insulated wires Insulating sleeves. The splicing of copper wires happens in the following steps: The cores are laid one above the other at the junction. The core insulation is removed. The wires are wrapped two to three times around each other .
The conduit methods were known to be of better quality, but cost significantly more than K&T. [2] In 1909, flexible armored cable cost about twice as much as K&T, and conduit cost about three times the price of K&T. [6] Knob and tube wiring persisted since it allowed owners to wire a building for electricity at lower cost.
"Pig-tailing" which involves splicing a short length of copper wire (pigtail) to the original aluminum wire, and then attaching the copper wire to the existing electrical device. The splice of the copper pigtail to the existing aluminum wire can be accomplished with special crimp connectors, special miniature lug-type connectors, or approved ...