When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Pad-mounted transformer - Wikipedia

    en.wikipedia.org/wiki/Pad-mounted_transformer

    ANSI C57.12.00 – Standard General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers ANSI C57.12.22 – Standard for Transformers - Pad-Mounted, Compartmental-Type, Self-Cooled, Three-Phase Distribution Transformers with High-Voltage Bushings, 2500 kVA and Smaller: High Voltage, 34,500Grd/19,920 Volts, and Below ...

  3. Electrical room - Wikipedia

    en.wikipedia.org/wiki/Electrical_room

    The construction features of an electrical room vary depending on the scope of the equipment to be installed. Floors may be reinforced to support heavy transformers and switchgear. Walls and ceilings may have to support a heavy cable tray system or busbars. Additional ventilation or air conditioning may be needed, since electrical apparatus ...

  4. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    By choosing the base quantities in this manner, the transformer can be effectively removed from the circuit as described above. For example: Take a transformer that is rated at 10 kVA and 240/100 V. The secondary side has an impedance equal to 1∠0° Ω. The base impedance on the secondary side is equal to:

  5. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Aerial transformers, larger than around 75 kVA, may be mounted on a platform supported by one or more poles. [13] A three-phase service may use three identical transformers, one per phase. Transformers designed for below-grade installation can be designed for periodic submersion in water. [14]

  6. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Transformers step down transmission voltages, 35 kV or more, down to primary distribution voltages. These are medium voltage circuits, usually 600–35 000 V. [1] From the transformer, power goes to the busbar that can split the distribution power off in multiple directions. The bus distributes power to distribution lines, which fan out to ...

  7. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    A conventional six-winding, grounding transformer or zigzag bank, [1] with the same winding and core quantity as a conventional three-phase transformer, can also be used in zigzag winding connection. In all cases the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core.

  8. Buck–boost transformer - Wikipedia

    en.wikipedia.org/wiki/Buck–boost_transformer

    Buck–boost transformers can be used to power low voltage circuits including control, lighting circuits, or applications that require 12, 16, 24, 32 or 48 volts, consistent with the design's secondaries. The transformer is connected as an isolating transformer and the nameplate kVA rating is the transformer’s capacity. [2]

  9. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V. A three-phase final step-down transformer is then used. One house gets phases A & B, the next house gets phase B & C, the third house gets phase A & C.

  1. Related searches standard transformer kva sizes to square feet calculator for painting ceiling

    per unit transformer voltagetransformer impedance formula
    transformer voltage ratingspad mounted transformer diagram
    transformer impedance ratio