white light scatter-plate interferometers. While all three of these interferometers work with a white light source, only the first, the diffraction grating interferometer, is truly achromatic. [8] Here the vertical scanning or coherence probe interferometers are discussed in detail due to their extensive use for surface metrology in today’s ...
Figure 3. White light interferometric microscope. White-light interferometry scanning (WLS) systems capture intensity data at a series of positions along the vertical axis, determining where the surface is located by using the shape of the white-light interferogram, the localized phase of the interferogram, or a combination of both shape and phase.
Coherence scanning interferometry (CSI) is any of a class of optical surface measurement methods wherein the localization of interference fringes during a scan of optical path length provides a means to determine surface characteristics such as topography, transparent film structure, and optical properties.
Optical coherence tomogram of a fingertip. It is possible to observe the sweat glands, having "corkscrew appearance" Interferometric reflectometry of biological tissue, especially of the human eye using short-coherence-length light (also referred to as partially-coherent, low-coherence, or broadband, broad-spectrum, or white light) was investigated in parallel by multiple groups worldwide ...
Watson interferometer (microscopy) White-light interferometer (see also Optical coherence tomography, White light interferometry, and Coherence Scanning Interferometry) White-light scatterplate interferometer (white-light) (microscopy) Young's double-slit interferometer; Zernike phase-contrast microscopy
Fig. 19 illustrates a Twyman–Green interferometer set up for white light scanning of a macroscopic object. Holographic interferometry is a technique which uses holography to monitor small deformations in single wavelength implementations. In multi-wavelength implementations, it is used to perform dimensional metrology of large parts and ...
They can also use coherence scanning interferometry (CSI) with a white-light source to measure steep or rough surfaces, including machined metal, foam, paper and more. As is the case with all optical techniques, the interaction of light with the sample for this instruments is not fully understood.
The Michelson interferometer splits one beam of light into two paths, one reference path and one sampling path, and recombines them again to produce a waveform resulting from interference. The difference between the reference beam and the sampling beam thus reveal the properties of the sample in the way it scatters light.