When.com Web Search

  1. Ads

    related to: 40a 2pole gfi breaker gftcb240

Search results

  1. Results From The WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  3. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    Such devices may be found in the form of either a circuit breaker, known as an earth-leakage circuit breaker (ELCB), or built into a socket (aka receptacle). Voltage-operated ELCBs can still be found in the wild, though these largely fell out of favour after the invention of the current-sensing based RCD (aka GFCI) technology.

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    Breakers for protections against earth faults too small to trip an over-current device: Residual-current device (RCD), or residual-current circuit breaker (RCCB) — detects current imbalance, but does not provide over-current protection. In the United States and Canada, these are called ground fault circuit interrupters (GFCI).

  5. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  6. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    After the 1970s, vacuum switches began to replace the minimal-oil switches in medium-voltage switchgear. In the early 1980s, SF6 switches and breakers were also gradually replaced by vacuum technology in medium-voltage application. As of 2018, a vacuum circuit breaker had reached 145 kV and the breaking current had reached 200 kA. [4]

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [ 5 ] Reclosers are often used as a key component in a smart grid , as they are effectively computer controlled switchgear which can be remotely operated and interrogated using supervisory ...

  1. Ad

    related to: 40a 2pole gfi breaker gftcb240