Search results
Results From The WOW.Com Content Network
The only hydrates with stable melting points are NaOH·H 2 O (65.10 °C) and NaOH·3.5H 2 O (15.38 °C). The other hydrates, except the metastable ones NaOH·3H 2 O and NaOH·4H 2 O (β) can be crystallized from solutions of the proper composition, as listed above.
For determining the acid value of mineral oils and biodiesel, there are standard methods such as ASTM D 974 and DIN 51558, and especially for biodiesel the European Standard EN 14104 and ASTM D664 are both widely used worldwide. [2] Acid value of biodiesel should be lower than 0.50 mg KOH/g in both EN 14214 and ASTM D6751 standard fuels.
In the International System of Units (SI), the coherent unit for molar concentration is mol/m 3. However, most chemical literature traditionally uses mol/dm 3, which is the same as mol/L. This traditional unit is often called a molar and denoted by the letter M, for example: 1 mol/m 3 = 10 −3 mol/dm 3 = 10 −3 mol/L = 10 −3 M = 1 mM = 1 ...
A primary standard in metrology is a standard that is sufficiently accurate such that it is not calibrated by or subordinate to other standards. Primary standards are defined via other quantities like length, mass and time. Primary standards are used to calibrate other standards referred to as working standards. [1] [2] See Hierarchy of Standards.
When choosing primary standards in analytical chemistry, compounds with higher equivalent weights are generally more desirable because weighing errors are reduced. An example is the volumetric standardisation of a solution of sodium hydroxide which has been prepared to approximately 0.1 mol dm −3 .
From left to right solutions of 0.1 M HCl, 3 buffer solutions of pH 3.78, 3 of pH 4.00, 3 of pH 4.62 and NaOH 0.1 M after adding different amounts of bromocresol green (more in darker solutions) In aqueous solution , bromocresol green will ionize to give the monoanionic form (yellow), that further deprotonates at higher pH to give the dianionic ...
A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume. The titrant reacts with a solution of analyte (which may also be termed the titrand [3]) to determine the analyte's concentration. The volume of titrant that reacted with the analyte is termed the titration volume.
The sample solution is then distilled with a small amount of sodium hydroxide (NaOH). [3] NaOH can also be added with a dropping funnel. [4] NaOH reacts the ammonium (NH 4 +) to ammonia (NH 3), which boils off the sample solution. Ammonia bubbles through the standard acid solution and reacts back to ammonium salts with the weak or strong acid. [3]