Ad
related to: nominal width of a 2x4 wall in meters chart for feet diameter
Search results
Results From The WOW.Com Content Network
Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...
A standard metric (concrete) block is 190 mm wide, 390 mm long, and 190 mm high, which allows for 10 mm mortar joints in between bricks, giving a standard unit size of 200 mm square by 400 mm long. [3] A standard metric brick is 90 by 57 by 190 mm; with 10 mm of mortar, that produces a standard unit of 100 mm x 200 mm. [3]
The pipe wall thickness has a variance of approximately 12.5 percent. In the rest of Europe pressure piping uses the same pipe IDs and wall thicknesses as Nominal Pipe Size, but labels them with a metric Diameter Nominal (DN) instead of the imperial NPS. For NPS larger than 14, the DN is equal to the NPS multiplied by 25.
Drill pipe is most often considered premium class, which is 80% remaining body wall (RBW). After inspection determines that the RBW is below 80%, the pipe is considered to be Class 2 or "yellow band" pipe. Eventually the drill pipe will be graded as scrap and marked with a red band. Drill pipe is a portion of the overall drill string.
The board foot or board-foot is a unit of measurement for the volume of lumber in the United States and Canada [1].It equals the volume of a board that is one foot (30.5 cm) in length, one foot in width, and one inch (2.54 cm) in thickness, or exactly 2.359 737 216 liters.
Steel studs are gaining popularity as a non-combustible alternative, especially for non load-bearing walls, and are required in some firewalls. In New Zealand, the required lumber size and spacing of wall studs are determined using NZS 3604 Timber-framed buildings table 8.2 for loadbearing walls and table 8.4 for non-loadbearing walls. [4]
Copper tubing, however, is measured in nominal size, 1 ⁄ 8 inch less than the outside diameter. The Schedule system is used for standard pipe thicknesses. Alcohol content is frequently given in proof, 2 × percent alcohol by volume; The cord is used for volume of firewood. The square is used to mean 100 square feet in construction.
In 1948, the DIPS came into effect, when greater control of a pipe's wall thickness was possible. CTS diameter always specifies the outside diameter (OD) of a tube, where pipe diameter specifications only approximate the pipe inside diameter (ID) for sizes of 12 inch or less, and STD wall thickness.