Search results
Results From The WOW.Com Content Network
The respiratory quotient (RQ or respiratory coefficient) is a dimensionless number used in calculations of basal metabolic rate (BMR) when estimated from carbon dioxide production. It is calculated from the ratio of carbon dioxide produced by the body to oxygen consumed by the body, when the body is in a steady state.
The respiratory quotient for protein metabolism can be demonstrated by the chemical equation for oxidation of albumin: C 72 H 112 N 18 O 22 S + 77 O 2 63 CO 2 + 38 H 2 O + SO 3 + 9 CO ( NH 2 ) 2 {\displaystyle {\ce {C72H112N18O22S + 77 O2 -> 63 CO2 + 38 H2O + SO3 + 9 CO(NH2)2}}}
In respiratory physiology, the ventilation/perfusion ratio (V/Q ratio) is a ratio used to assess the efficiency and adequacy of the ventilation-perfusion coupling and thus the matching of two variables: V – ventilation – the air that reaches the alveoli; Q – perfusion – the blood that reaches the alveoli via the capillaries
The partial pressure of oxygen (pO 2) in the pulmonary alveoli is required to calculate both the alveolar-arterial gradient of oxygen and the amount of right-to-left cardiac shunt, which are both clinically useful quantities. However, it is not practical to take a sample of gas from the alveoli in order to directly measure the partial pressure ...
Once this is known, the total metabolic rate may be estimated from simplifying assumptions regarding the ratio of oxygen used in metabolism (and therefore heat generated), to carbon dioxide eliminated (see respiratory quotient). This quotient can be measured in other ways, and almost always has a value between 0.7 and 1.0, and for a mixed diet ...
The Shunt equation (also known as the Berggren equation) quantifies the extent to which venous blood bypasses oxygenation in the capillaries of the lung.. “Shunt” and “dead space“ are terms used to describe conditions where either blood flow or ventilation do not interact with each other in the lung, as they should for efficient gas exchange to take place.
But most importantly, the study found that essentially the more you walk, the better – every extra 1,000 steps was associated with a 15% decreased risk of dying from any cause, and a mere extra ...
When estimating static lung compliance, volume measurements by the spirometer needs to be complemented by pressure transducers in order to simultaneously measure the transpulmonary pressure. When having drawn a curve with the relations between changes in volume to changes in transpulmonary pressure, C st is the slope of the curve during any ...