    No inherent redundancy for the pump. A zone-valved system is dependent upon a single circulator pump. If it fails, the system becomes completely inoperable. The system can be harder to design, requiring both "SPDT" thermostats or relays and the ability of the system to withstand the fault condition whereby all zone valves are closed simultaneously.

  3. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    This avoids one of the principal challenges faced by the larger, two-part pumps: maintaining a water-tight seal at the point where the pump drive shaft enters the pump body. Small- to medium-sized circulator pumps are usually supported entirely by the pipe flanges that join them to the rest of the hydronic plumbing. Large pumps are usually pad ...

  4. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    A reduced pressure zone device (RPZD, RPZ, or RPZ valve) is a type of backflow prevention device used to protect water supplies from contamination. RPZDs may also be known as reduced pressure principle (RP), reduced pressure principle backflow prevention devices , [ 1 ] [ 2 ] reduced pressure zone assemblies (RPZA), [ 3 ] or reduced pressure ...

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    This allows a more granular application of heat, similar to non-central heating systems. Zones are controlled by multiple thermostats. In water heating systems the thermostats control zone valves, and in forced air systems they control zone dampers inside the vents which selectively block the flow of air. In this case, the control system is ...

  6. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    In general, valves nearest to the boiler should vent the slowest, and valves furthest from the boiler should vent the fastest. [citation needed] Ideally, steam should reach each valve and close each and every valve at the same time, so that the system can work at maximal efficiency; this condition is known as a "balanced" system. [citation needed]

  7. Hydronic balancing - Wikipedia

    en.wikipedia.org/wiki/Hydronic_balancing

    Some circuits (typically those closest to the pump) will be favored by higher than required flows at the expense of other circuits that will have underflows. Control valves may temporarily help by gradually reducing the flow in favoured circuits, thus allowing unfavored circuits to achieve the correct flow.