Search results
Results From The WOW.Com Content Network
Alternatively, drainage tubes are passed over the guidewire (as in chest drains or nephrostomies). After passing a sheath or tube, the guidewire is withdrawn. [1] An introducer sheath can be used to introduce catheters or other devices to perform endoluminal (inside the hollow organ) procedures, such as angioplasty.
Used for example in steady advancement of the catheter on a guidewire previously inserted into the renal pelvis through a thin needle. D. Both obturator and puncture needle retracted, when the catheter is in the renal pelvis. E. Locking string is pulled (bottom center) and then wrapped and attach to the superficial end of the catheter.
After successful insertion of the guidewire, pressure in fossa is released and the subclavian vein catheter is railroaded over the guidewire up to the desired length. The guidewire is removed and the catheter is now connected to the transducer and the monitor. The CVP waveform pattern as well as its value is noted.
A vascular snare is an endovascular device that is used to remove foreign bodies from inside arteries and veins.The snare consists of several radiopaque loops of wire inside a catheter, which when extended flower out, and which collapse when withdrawn into the catheter.
Venous cutdown is an emergency procedure in which the vein is exposed surgically and then a cannula is inserted into the vein under direct vision. It is used for venous access in cases of trauma, and hypovolemic shock when the use of a peripheral venous catheter is either difficult or impossible.
The surgeon will remove the catheter three to seven days after the surgery is completed. A baseline uroflowmetric study will be performed, and the patient will be instructed to return in thirty days for a follow-up evaluation. This evaluation will include another uroflowmetric study and a complete urinalysis.
A ureteric balloon catheter is a balloon catheter intended for treating strictures of the ureter. In fact it is a double J stent on which a balloon is mounted. It is connected to a delivery device (pusher) to introduce it from the bladder into the ureter. The system comprises a non-return valve device, and a pusher with a stylet and two ports.
Catheter access, sometimes called a CVC (central venous catheter), consists of a plastic catheter with two lumens (or occasionally two separate catheters) which is inserted into a large vein (usually the vena cava, via the internal jugular vein or the femoral vein) to allow large flows of blood to be withdrawn from one lumen, to enter the dialysis circuit, and to be returned via the other lumen.