Ads
related to: tantec contact angle meter
Search results
Results From The WOW.Com Content Network
Cloth, treated to be hydrophobic, shows a high contact angle. The theoretical description of contact angle arises from the consideration of a thermodynamic equilibrium between the three phases: the liquid phase (L), the solid phase (S), and the gas or vapor phase (G) (which could be a mixture of ambient atmosphere and an equilibrium concentration of the liquid vapor).
The simplest way of measuring the contact angle of a sessile drop is with a contact angle goniometer, which allows the user to measure the contact angle visually. A droplet is deposited by a syringe which is positioned above the sample surface, and a high resolution camera captures the image from the profile or side view.
The first contact angle goniometer was designed by William Zisman of the United States Naval Research Laboratory in Washington, D.C. and manufactured by ramé-hart (now ramé-hart instrument company), New Jersey, USA. The original manual contact angle goniometer used an eyepiece with a microscope.
The captive bubble method is a method for measuring the contact angle between a liquid and a solid, by using drop shape analysis. [1] In this method, a bubble of air is injected beneath a solid, the surface of which is located in the liquid, instead of placing a drop on the solid as in the case of the sessile drop technique.
If water has a contact angle between < <, then the surface is classed as hydrophilic, whereas a surface producing a contact angle between < < is hydrophobic. In the special cases where the Contact angle is 150 ∘ < θ {\displaystyle 150^{\circ }<\theta } , then it is known as superhydrophobic.
Luminance meter for measuring luminance, i.e. luminous flux per unit area and unit solid angle; Light meter, an instrument used to set photographic exposures. It can be either a lux meter (incident-light meter) or a luminance meter (reflected-light meter), and is calibrated in photographic units.
The Wilhelmy plate tensiometer requires a plate to make contact with the liquid surface. It is widely considered the simplest and most accurate method for surface tension measurement. Due to a large wetted length of the platinum plate, the surface tension reading is typically very stable compared to alternative methods.
When a tube of a narrow bore, often called a capillary tube, is dipped into a liquid and the liquid wets the tube (with zero contact angle), the liquid surface inside the tube forms a concave meniscus, which is a virtually spherical surface having the same radius, r, as the inside of the tube. The tube experiences a downward force of magnitude ...