When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Ductwork airtightness - Wikipedia

    en.wikipedia.org/wiki/Ductwork_airtightness

    The relationship between pressure and leakage air flow rate is defined by the power law model between the airflow rate and the pressure difference across the ductwork envelope as follows: q L =C L ∆p n. where: q L is the volumetric leakage airflow rate expressed in L.s −1; C L is the air leakage coefficient expressed in L.s −1.Pa −n

  3. Building airtightness - Wikipedia

    en.wikipedia.org/wiki/Building_airtightness

    The airtightness of a building is often expressed in terms of the leakage airflow rate through the building's envelope at a given reference pressure (usually 50 pascal) [10] divided by the: Heated building volume V. At 50·Pa, it is called the air change rate at 50 Pa and usually noted n 50 (units: h −1). [13] [14] Envelope area A E.

  4. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    The airflow, (Imperial in Cubic Feet / minute; SI in liters / second) at a given building-to-outside pressure differential, 50 pascal (Q 50). This standardized single-point test allows for comparison between homes measured at the same reference pressure. This is a raw number reflecting only the flow of air through the fan.

  5. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    In cold climates, with a 15 MPH wind, residences often have air exchange rates of 1.0 to 1.5 ACHs, far in excess of the ventilation air needs and are thus called loose construction. It is very easy to reduce infiltration rates to less than 1.0 ACH. Smoke candles and blower-door tests can help identify less-than-obvious leaks.

  6. Automatic bleeding valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_bleeding_valve

    An automatic bleeding valve or air release valve (ARV) is a plumbing valve used to automatically release trapped air from a heating system. Air, or other gas, may collect within plumbing. For water delivery systems to taps and basins, particularly with good main supply pressure, this air is usually flushed through with the water flow and does ...

  7. Diffuser (thermodynamics) - Wikipedia

    en.wikipedia.org/wiki/Diffuser_(thermodynamics)

    Diffusers can be as a shape of round, rectangular, or can be as linear slot diffusers (LSDs). E.g., linear slot diffusers take the form of one or several long, narrow slots, mostly semi-concealed in a fixed or suspended ceiling with airfoils behind the slots directing the airflow in the desired direction.

  8. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    Air can be exhausted through pressurized hoods or the use of fans and pressurizing a specific area. [35] A local exhaust system is composed of five basic parts: A hood that captures the contaminant at its source; Ducts for transporting the air; An air-cleaning device that removes/minimizes the contaminant; A fan that moves the air through the ...

  9. Pneumatic circuit - Wikipedia

    en.wikipedia.org/wiki/Pneumatic_circuit

    The combination throttle valve connected to the check valve is called a one way flow control valve. While air passes from one direction to the other, the check valve will not allow air flow as the check valve allows flow only in one direction. While passing through the restricted way of throttle, compressed air flow takes place.