When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...

  3. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a " dry basis " concentration: [ 3 ]

  4. Density of air - Wikipedia

    en.wikipedia.org/wiki/Density_of_air

    To calculate the density of air as a function of altitude, one requires additional parameters. For the troposphere, the lowest part (~10 km) of the atmosphere, they are listed below, along with their values according to the International Standard Atmosphere , using for calculation the universal gas constant instead of the air specific constant:

  5. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  6. Mass flow rate - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_rate

    The area required to calculate the mass flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface, e.g. for substances passing through a filter or a membrane, the real surface is the (generally curved) surface area of the filter, macroscopically - ignoring the area spanned by the holes in the filter/membrane ...

  7. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .

  8. Help:Convert units - Wikipedia

    en.wikipedia.org/wiki/Help:Convert_units

    Unit type Unit code Unit name Area: a: are: m2: square metre Charge: coulomb: coulomb Energy: J: joule Force: N: newton Length: m: metre Magnetic field strength: T ...

  9. Specific volume - Wikipedia

    en.wikipedia.org/wiki/Specific_volume

    The table below displays densities and specific volumes for various common substances that may be useful. The values were recorded at standard temperature and pressure, which is defined as air at 0 °C (273.15 K, 32 °F) and 1 atm (101.325 kN/m 2, 101.325 kPa, 14.7 psia, 0 psig, 30 in Hg, 760 torr). [4]