When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. ASHRAE 55 - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_55

    ANSI/ASHRAE Standard 55 was first published in 1966. It was revised in 1974, 1981, 1992, 2004, 2010, 2013, 2017, 2020 and 2023. Starting in 2004, it is now updated based on ASHRAE's standard maintenance procedures. These periodic revisions are based on a publicly reviewed addenda to the previous version available on ASHRAE's website. [13]

  3. United States building energy codes - Wikipedia

    en.wikipedia.org/wiki/United_States_building...

    ASHRAE 90.1 follows a similar path of development and revision. [6] Though ASHRAE 90.1 is revised and published every three years just like the IECC, people can submit interim revisions at any time within this period. [5] ASHRAE has a standards committee that manages the process, and votes on the final versions of the energy code. [5]

  4. ASHRAE Handbook - Wikipedia

    en.wikipedia.org/wiki/ASHRAE_Handbook

    Members of ASHRAE receive the current volume, in both print and CD-ROM form, each year as a basic membership benefit. An enhanced electronic version, known as ASHRAE Handbook Online is a web-based version updated annually that contains the four latest volumes as well as extra content such as calculations, demonstration videos, and spreadsheets ...

  5. ASHRAE - Wikipedia

    en.wikipedia.org/wiki/ASHRAE

    ASHRAE was founded in 1894 at a meeting of engineers in New York City, formerly headquartered at 345 East 47th Street, and has held an annual meeting since 1895. [4] Until 1954 it was known as the American Society of Heating and Ventilating Engineers (ASHVE); in that year it changed its name to the American Society of Heating and Air-Conditioning Engineers (ASHAE). [5]

  6. Thermal comfort - Wikipedia

    en.wikipedia.org/wiki/Thermal_comfort

    ASHRAE Standard 55-2017 uses the PMV model to set the requirements for indoor thermal conditions. It requires that at least 80% of the occupants be satisfied. [1] The CBE Thermal Comfort Tool for ASHRAE 55 [9] allows users to input the six comfort parameters to determine whether a certain combination complies with ASHRAE 55.

  7. Air filtration in operating rooms - Wikipedia

    en.wikipedia.org/wiki/Air_filtration_in...

    Air filtration standards differ between the U.S. and other countries. The American ASHRAE rating system does not account for changes in filtration efficiency due to electrostatic charge. These MERV ratings do not account for a decrease in efficiency over the first few weeks of use due to a drop in static charge.

  8. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour is a measurement intended to communicate the air change effectiveness of a space’s ventilation system. Discussion around the ASHRAE standard 62, Ventilation for Acceptable Indoor Air Quality led to the development of a more direct method of measuring air change effectiveness with the use of a tracer gas. [1]

  9. Radiant heating and cooling - Wikipedia

    en.wikipedia.org/wiki/Radiant_heating_and_cooling

    Some standards suggest a limit for the relative humidity in a space to 60% or 70%. An air temperature of 26 °C (79 °F) would mean a dew point between 17 and 20 °C (63 and 68 °F). [ 13 ] There is, however, evidence that suggests decreasing the surface temperature to below the dew point temperature for a short period of time may not cause ...