When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Bioburden - Wikipedia

    en.wikipedia.org/wiki/Bioburden

    The term is most often used in the context of bioburden testing, also known as microbial limit testing, which is performed on pharmaceutical products and medical products for quality control purposes. Products or components used in the pharmaceutical or medical field require control of microbial levels during processing and handling. Bioburden ...

  3. Chemical test - Wikipedia

    en.wikipedia.org/wiki/Chemical_test

    The Griess test tests for organic nitrite compounds; The 2,4-dinitrophenylhydrazine tests for carbonyl compounds; The iodoform reaction tests for the presence of methyl ketones, or compounds which can be oxidized to methyl ketones; The Schiff test detects aldehydes; Tollens' reagent tests for aldehydes (known as the silver mirror test)

  4. Analytical quality control - Wikipedia

    en.wikipedia.org/wiki/Analytical_quality_control

    All analytical procedures should be validated. Identification tests are conducted to ensure the identity of an analyte in a sample through comparison of the sample to a reference standard through methods such as spectrum, chromatographic behavior, and chemical reactivity. [5] Impurity testing can either be a quantitative test or a limit test.

  5. Upgrade to a faster, more secure version of a supported browser. It's free and it only takes a few moments:

  6. Bresle method - Wikipedia

    en.wikipedia.org/wiki/Bresle_method

    The solubility in water depends on the type of salt. Sodium chloride can be dissolved in cold water to a concentration of 357 g∙l −1. Not only solubility differs between salts but also the conductivity. When performing a Bresle method test, not only sodium chloride is dissolved but also all other salts present on the surface.

  7. Detection limit - Wikipedia

    en.wikipedia.org/wiki/Detection_limit

    In analytical chemistry, the detection limit, lower limit of detection, also termed LOD for limit of detection or analytical sensitivity (not to be confused with statistical sensitivity), is the lowest quantity of a substance that can be distinguished from the absence of that substance (a blank value) with a stated confidence level (generally 99%).

  8. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  9. Dutch pollutant standards - Wikipedia

    en.wikipedia.org/wiki/Dutch_pollutant_standards

    An arbitrary limit of 10 metres has been adopted. The target values shown below are for 'shallow' groundwater, 0 – 10 m depth. The soil remediation intervention values indicate when the functional properties of the soil for humans, plants and animals is seriously impaired or threatened.