A normal nonstress test will show a baseline fetal heart rate between 110 and 160 beats per minute with moderate variability (5- to 25-interbeat variability) and 2 qualifying accelerations in 20 minutes with no decelerations. "Reactive" is defined as the presence of two or more fetal heart rate accelerations within a 20-minute period. Each ...
Category III (Abnormal): Tracing is predictive of abnormal fetal acid-base status at the time of observation; this requires prompt evaluation and management. Absence of baseline variability, with recurrent late/variable decelerations or bradycardia; or; Sinusoidal fetal heart rate.
While continuous fetal heart rate monitoring is the primary method for assessing fetal wellbeing during labor, a change in fetal heart rate is not indicative of fetal acidemia. [1] [2] Some of the signs and symptoms of oxygen deprivation are pH in the umbilical cord, abnormal fetal heartbeat and abnormal coloration of amniotic fluid.
The presence of these biophysical variables implies absence of significant central nervous system hypoxemia/acidemia at the time of testing. By comparison, a compromised fetus typically exhibits loss of accelerations of the fetal heart rate (FHR), decreased body movement and breathing, hypotonia, and, less acutely, decreased amniotic fluid volume.
During uterine contractions, fetal oxygenation is worsened. Late decelerations in fetal heart rate occurring during uterine contractions are associated with increased fetal death rate, growth retardation and neonatal depression. [1] [2] This test assesses fetal heart rate in response to uterine contractions via electronic fetal monitoring.
It is characterized by changes in fetal movement, growth, heart rate, and presence of meconium stained fluid. [4] Risk factors for fetal distress/non-reassuring fetal status include anemia, restriction of fetal growth, maternal hypertension or cardiovascular disease, low amniotic fluid or meconium in the amniotic fluid, or a post-term pregnancy.
Fetal heart rate is continuously monitored for slow or abnormal heart rate patterns which may indicate fetal distress during labor. [7] If the exposed blood vessels are near the cervix or are at risk of rupturing, the newborn may be delivered via caesarean section as early as 35 weeks gestation.
Fetal development, neural tube defects, birth defects, and various other physical abnormalities (see below for specific ultrasound tests) NA Fetal heart-rate monitoring [9] Week 12 – onward Non-invasive Handheld abdominal doppler or fetoscope: Immediately Heart rate irregularities NA Genetic prenatal rests Carrier screening (Screen) [10]