When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    Breaking capacity or interrupting rating [1] [2] is the current that a fuse, circuit breaker, ... Making capacity i.e. maximum fault current , device can carry, ...

  3. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  4. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  5. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  6. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    All circuit breaker systems have common features in their operation, but details vary substantially depending on the voltage class, current rating and type of the circuit breaker. The circuit breaker must first detect a fault condition. In small mains and low-voltage circuit breakers, this is usually done within the device itself. Typically ...

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    If the fault is on an adjacent circuit to the customer, the customer may see several brief "dips" (sags) in voltage as the heavy fault current flows into the adjacent circuit and is interrupted one or more times. A typical manifestation would be the dip, or intermittent black-out, of domestic lighting during an electrical storm.

  8. Arc flash - Wikipedia

    en.wikipedia.org/wiki/Arc_flash

    Fault current can be limited by using current limiting devices such as current limiting breakers, grounding resistors, arc suppression coils or fuses. If the fault current is limited to 5 amperes or less, then many ground faults self-extinguish and do not propagate into phase-to-phase faults.

  9. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    A fault current limiter is a nonlinear element which has a low impedance at normal current levels, but presents a higher impedance at fault current levels. Further, this change is extremely rapid, before a circuit breaker can trip a few milliseconds later.