When.com Web Search

  1. Ads

    related to: how to duct an erv 2 box with water connection system for small

Search results

  1. Results From The WOW.Com Content Network
  2. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  3. Air-mixing plenum - Wikipedia

    en.wikipedia.org/wiki/Air-mixing_plenum

    The most common application for an air-mixing plenum is the mixing of return air (or extract air) with fresh air to provide a supply air mixture for onward distribution to the building or area which the ventilation system is serving. [1] The air transferred from the return air stream to the supply air stream is termed recirculated air.

  4. Constant air volume - Wikipedia

    en.wikipedia.org/wiki/Constant_air_volume

    [2] The terminal reheat system cools the air in the air handling unit down to the lowest possible needed temperature within its zone of spaces. This supplies a comfortable quality to the space, but wastes energy. The mixed air system has two air streams, typically one for the coldest and one for the hottest needed air temperature in the zone.

  5. Heat recovery steam generator - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_steam_generator

    Some HRSGs include supplemental, or duct firing. These additional burners provide additional energy to the HRSG, which produces more steam and hence increases the output of the steam turbine. Generally, duct firing provides electrical output at lower capital cost. It is therefore often utilized for peaking operations.

  6. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    Round duct elbow allowable stresses are lower than the allowable stresses for straight duct by a K factor = 1.65/(h 2/3power) where h = t (duct) * R (elbow) /(r(duct)*r (duct). This equation, or similar equations is found in Tubular Steel Structures section 9.9. Rectangular ductwork design properties is based on width-to-thickness ratios.

  7. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.