Search results
Results From The WOW.Com Content Network
X-ray absorption spectroscopy (XAS) is a widely used technique for determining the local geometric and/or electronic structure of matter. [1] The experiment is usually performed at synchrotron radiation facilities, which provide intense and tunable X-ray beams. Samples can be in the gas phase, solutions, or solids. [2]
Anomalous X-ray scattering (MAD or SAD phasing) – the X-ray wavelength may be scanned past an absorption edge [a] of an atom, which changes the scattering in a known way. By recording full sets of reflections at three different wavelengths (far below, far above and in the middle of the absorption edge) one can solve for the substructure of ...
The x-ray absorption coefficient is usually normalized to unit step height. This is done by regressing a line to the region before and after the absorption edge, subtracting the pre-edge line from the entire data set and dividing by the absorption step height, which is determined by the difference between the pre-edge and post-edge lines at the ...
An X-ray spectrograph consists of a high voltage power supply (50 kV or 100 kV), a broad band X-ray tube, usually with a tungsten anode and a beryllium window, a specimen holder, an analyzing crystal, a goniometer, and an X-ray detector device. These are arranged as shown in Fig. 1.
The XANES energy region [3] extends between the edge region and the EXAFS region over a 50-100 eV energy range around the core level x-ray absorption threshold. Before 1980 the XANES region was wrongly assigned to different final states: a) unoccupied total density of states, or b) unoccupied molecular orbitals (kossel structure) or c) unoccupied atomic orbitals or d) low energy EXAFS ...
X-ray absorption near edge structure (XANES), also known as near edge X-ray absorption fine structure (NEXAFS), is a type of absorption spectroscopy that indicates the features in the X-ray absorption spectra of condensed matter due to the photoabsorption cross section for electronic transitions from an atomic core level to final states in the energy region of 50–100 eV above the selected ...
Metal K-edge spectroscopy is a spectroscopic technique used to study the electronic structures of transition metal atoms and complexes.This method measures X-ray absorption caused by the excitation of a 1s electron to valence bound states localized on the metal, which creates a characteristic absorption peak called the K-edge.
It shows the electronic transitions for 2p→3d (L-edge) absorption. It is not to scale. In the case of transition metals such as iron, cobalt, and nickel, the absorption spectra for XMCD are usually measured at the L-edge. This corresponds to the process in the iron case: with iron, a 2p electron is excited to a 3d state by an X-ray of about ...