When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  3. Talk:Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Talk:Residual-current_device

    For example, my rather small house has a 42 pole panelboard (only about 20 poles installed, though; 240 volt appliances get 2-pole circruit breakers), 200 ampere main circuit breaker, with no GFCI circuit breakers mounted and only one AFCI panel mounted circuit breaker for the bedroom receptacles; there are GFCI receptacles for bathroom ...

  4. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices. Requirement of an additional third wire from the load to the devices. Separate devices cannot be grounded individually. Any additional connection to Earth on the protected system can disable the detector.

  5. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Most GFCI receptacles allow the connection and provide GFCI protection for down-stream connected receptacles. Receptacles protected in this manner or with a GFCI circuit breaker should be labeled "GFCI protected". (Outside North America these are referred to as a "Residual-current device" or RCD.)

  6. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    In addition, a tripped GFCI receptacle may be more easily noticed and reset, as compared to a tripped GFCI located in a remote circuit breaker panel far from the point of usage. Like most current interrupting devices, a GFCI receptacle can optionally be wired to feed additional "downstream" outlets; correctly installing one GFCI receptacle in a ...

  7. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    In the United States and Canada, these are called GFCI breakers. Earth leakage circuit breaker (ELCB) — This detects current in the earth wire directly rather than detecting imbalance. They are no longer seen in new installations as they cannot detect any dangerous condition where the current is returning to earth by another route – such as ...

  8. Distribution board - Wikipedia

    en.wikipedia.org/wiki/Distribution_board

    A distribution board (also known as panelboard, circuit breaker panel, breaker panel, electric panel, fuse box or DB box) is a component of an electricity supply system that divides an electrical power feed into subsidiary circuits while providing a protective fuse or circuit breaker for each circuit in a common enclosure.

  9. Electrical wiring in the United Kingdom - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_the...

    Residual-current device (RCD), also residual current circuit breaker (RCCB) A circuit breaker triggered by unequal currents in line and neutral wires (i.e., electrical power is passing to earth). Mandatory for most circuits as of 17th Edition regulations. Residual current circuit breaker with overcurrent protection (RCBO)