Search results
Results From The WOW.Com Content Network
The Ripper Method, developed in 1898, [1] is an analytical chemistry technique used to determine the total amount of sulfur dioxide (SO 2) in a solution.This technique uses iodine standard and a starch indicator to titrate the solution and determine the concentration of free SO 2.
The word "titration" descends from the French word titrer (1543), meaning the proportion of gold or silver in coins or in works of gold or silver; i.e., a measure of fineness or purity. Tiltre became titre, [4] which thus came to mean the "fineness of alloyed gold", [5] and then the "concentration of a substance in a given sample". [6]
Depending on the conditions in which the titration is performed, the manganese is reduced from an oxidation of +7 to +2, +4, or +6. In most cases, permanganometry is performed in a very acidic solution in which the following electrochemical reaction occurs: [3] MnO − 4 + 8 H + + 5 e − → Mn 2+ + 4 H 2 O; E° = +1.51 V [4]
In analytical chemistry, a standard solution (titrant or titrator) is a solution containing an accurately known concentration.Standard solutions are generally prepared by dissolving a solute of known mass into a solvent to a precise volume, or by diluting a solution of known concentration with more solvent. [1]
Although KF is a destructive analysis, the sample quantity is small and is typically limited by the accuracy of weighing. For example, in order to obtain an accuracy of 1% using a scale with the typical accuracy of 0.2 mg, the sample must contain 20 mg water, which is e.g. 200 mg for a sample with 10% water.
The term also has two other, conflicting meanings. In titration, the titer is the ratio of actual to nominal concentration of a titrant, e.g. a titer of 0.5 would require 1/0.5 = 2 times more titrant than nominal. This is to compensate for possible degradation of the titrant solution.
One process for X-ray fluorescence assay involves melting the material in a furnace and stirring to make a homogeneous mix. Following this, a sample is taken from the centre of the molten sample. Samples are typically taken using a vacuum pin tube. [4] The sample is then tested by X-ray fluorescence spectroscopy. Metallurgical assay is ...
A thermometric titration methodology which cannot be emulated using other types of titration sensors will deliver superior or results otherwise unobtainable by other techniques. Examples are the determination of fluoride by titration with boric acid, the analysis of orthophosphate by titration with magnesium ions, and the direct titration of ...