Search results
Results From The WOW.Com Content Network
Frequency. 1-13% [1] Benign early repolarization (BER) or early repolarization is found on an electrocardiogram (ECG) in about 1% of those with chest pain. [2] It is diagnosed based on an elevated J-point / ST elevation with an end-QRS notch or end-QRS slur and where the ST segment concave up. It is believed to be a normal variant.
An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...
Sgarbossa's criteria. Three criteria are included in Sgarbossa's criteria: [2] ST elevation ≥1 mm in a lead with a positive QRS complex (i.e.: concordance) - 5 points. concordant ST depression ≥1 mm in lead V1, V2, or V3 - 3 points. ST elevation ≥5 mm in a lead with a negative (discordant) QRS complex - 2 points.
Specialty. Cardiology, Emergency Medicine. Left bundle branch block (LBBB) is a conduction abnormality in the heart that can be seen on an electrocardiogram (ECG). [1] In this condition, activation of the left ventricle of the heart is delayed, which causes the left ventricle to contract later than the right ventricle.
Wellens' syndrome is an electrocardiographic manifestation of critical proximal left anterior descending (LAD) coronary artery stenosis in people with unstable angina. Originally thought of as two separate types, A and B, it is now considered an evolving wave form, initially of biphasic T wave inversions and later becoming symmetrical, often ...
Left axis deviation. The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.
Right axis deviation. The electrical axis of the heart is the net direction in which the wave of depolarization travels. It is measured using an electrocardiogram (ECG). Normally, this begins at the sinoatrial node (SA node); from here the wave of depolarisation travels down to the apex of the heart. The hexaxial reference system can be used to ...
Diagnosis is based on an ECG showing ST-segment depression at the J-point of 1 to 3 mm in leads V1 to V6, with tall and symmetrical T waves. [1] The ST-segment is upsloping and there is also often ST-segment elevation of 0.5 to 2 mm in lead aVR. [1] [2] The QRS complex is either normal or slightly wide. [1]