When.com Web Search

  1. Ads

    related to: sprinkler pump size calculator canada post standard shipping time frame

Search results

  1. Results From The WOW.Com Content Network
  2. Hydraulic calculation - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_calculation

    The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance.

  3. Purolator Inc. - Wikipedia

    en.wikipedia.org/wiki/Purolator_Inc.

    Purolator Inc. is a Canadian courier majority owned by Canada Post. It was founded as Trans Canada Couriers, Ltd and acquired in 1967 by Purolator, a US manufacturer of oil and air filters. [3] In 1987, the company returned to Canadian ownership. Although it retained the Purolator name, it has had no connection with the oil filter business ...

  4. Fire pump - Wikipedia

    en.wikipedia.org/wiki/Fire_pump

    The main standard that governs fire pump fixed-place installations in North America is the National Fire Protection Association's NFPA 20 Standard for the Installation of Stationary Fire Pumps for Fire Protection. [1] Fire pumps are powered most commonly by an electric motor or a diesel engine, or, occasionally a steam turbine.

  5. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.

  6. Center-pivot irrigation - Wikipedia

    en.wikipedia.org/wiki/Center-pivot_irrigation

    A satellite image of circular fields characteristic of center pivot irrigation, Kansas Farmland with circular pivot irrigation. Center-pivot irrigation (sometimes called central pivot irrigation), also called water-wheel and circle irrigation, is a method of crop irrigation in which equipment rotates around a pivot and crops are watered with sprinklers.

  7. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    The response time is expressed as a response time index (RTI), which typically has values between 35 and 250 m ½ s ½, where a low value indicates a fast response. [29] Under standard testing procedures (135 °C air at a velocity of 2.5 m/s), a 68 °C sprinkler bulb will break within 7 to 33 seconds, depending on the RTI. [30]

  8. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    This avoids one of the principal challenges faced by the larger, two-part pumps: maintaining a water-tight seal at the point where the pump drive shaft enters the pump body. Small- to medium-sized circulator pumps are usually supported entirely by the pipe flanges that join them to the rest of the hydronic plumbing .

  9. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A maximum of 60 seconds is normally allowed by regulatory requirements from the time a single sprinkler opens until water is discharged onto the fire. This delay in fire suppression results in a larger fire prior to control, increasing property damage. Dry pipe sprinkler system supply main with corrosion debris caused by oxidation