To match the termination at 800 MHz, a series capacitor of 2.6 pF must be placed in series with the transmission line at a distance of 29.6 mm from the termination. An alternative shunt match could be calculated after performing a Smith chart transformation from normalised impedance to normalised admittance.
In electrical engineering, impedance matching is the practice of designing or adjusting the input impedance or output impedance of an electrical device for a desired value. Often, the desired value is selected to maximize power transfer or minimize signal reflection .
In RF (radio frequency) applications, the L network is the basis of many common impedance matching circuits, such as the pi network employed in amplifiers and the T network that is common in transmatches. The L network relies on a procedure known as series-parallel transformation.
Stubs can match a load impedance to the transmission line characteristic impedance. The stub is positioned a distance from the load. This distance is chosen so that at that point, the resistive part of the load impedance is made equal to the resistive part of the characteristic impedance by impedance transformer action of the length of the main ...
SWR is used as a measure of impedance matching of a load to the characteristic impedance of a transmission line carrying radio frequency (RF) signals. This especially applies to transmission lines connecting radio transmitters and receivers with their antennas, as well as similar uses of RF cables such as cable television connections to TV receivers and distribution amplifiers.
Any component of the transmission line that has an input and output will contribute to the overall mismatch loss of the system. For example, in mixers mismatch loss occurs when there is an impedance mismatch between the RF port and IF port of the mixer [dubious – discuss]. [4] This is one of the principal reasons for losses in mixers.
Z in = the impedance seen looking into the input port when Z Load is connected to the output port. Z in is a function of the load impedance. Z out = the impedance seen looking into the output port when Z s is connected to the input port. Z out is a function of the source impedance. V s = source open circuit or unloaded voltage.
An SWR meter does not measure the actual impedance of a load (the resistance and reactance), but only the mismatch ratio. To measure the actual impedance requires an antenna analyzer or other similar RF measuring device. For accurate readings, the SWR meter itself must also match the line's impedance (typically 50 or 75 Ohms).