When.com Web Search

  1. Ads

    related to: auxiliary electrode for steel tube size 2

Search results

  1. Results From The WOW.Com Content Network
  2. Auxiliary electrode - Wikipedia

    en.wikipedia.org/wiki/Auxiliary_electrode

    The auxiliary electrode may be isolated from the working electrode using a glass frit. Such isolation prevents any byproducts generated at the auxiliary electrode from contaminating the main test solution: for example, if a reduction is being performed at the working electrode in aqueous solution, oxygen may be evolved from the auxiliary electrode.

  3. Cyclic voltammetry - Wikipedia

    en.wikipedia.org/wiki/Cyclic_voltammetry

    The counter electrode, also known as the auxiliary or second electrode, can be any material that conducts current easily, will not react with the bulk solution, and has a surface area much larger than the working electrode. Common choices are platinum and graphite. Reactions occurring at the counter electrode surface are unimportant as long as ...

  4. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    Both of these electrodes are balanced by a single reference and auxiliary combination for an overall four-electrode design. More complicated experiments may add working electrodes, reference, or auxiliary electrodes as required. [7] In practice it can be important to have a working electrode with known dimensions and surface characteristics.

  5. Submerged-arc furnace for phosphorus production - Wikipedia

    en.wikipedia.org/wiki/Submerged-arc_furnace_for...

    The electrode current is kept fairly constant during operation by automatically raising and lowering the electrodes. When current increases, the electrodes are raised, increasing the electrical resistance between the electrodes and the furnace floor. Hence reducing the current, produces the opposite effect when the voltage is kept constant.

  6. Cathodic protection - Wikipedia

    en.wikipedia.org/wiki/Cathodic_protection

    The choice of groundbed type and size depends on the application, location and soil resistivity. [22] The DC cathodic protection current is then adjusted to the optimum level after conducting various tests including measurements of pipe-to-soil potentials or electrode potential.

  7. Screen-printed electrodes - Wikipedia

    en.wikipedia.org/wiki/Screen-printed_electrodes

    It is the electrode that completes the circuit of the three-electrode cell, as it allows the passage of current. It enables the analysis of processes in which electronic transfer takes place. Screen-printed electrode with the three electrode system, reference electrode (RE), working electrode (WE) and auxiliary or counter electrode (AE or CE)

  8. Submerged arc welding - Wikipedia

    en.wikipedia.org/wiki/Submerged_arc_welding

    Electrodes are available in straight lengths and coils. Their diameters may be 1.6, 2.0, 2.4, 3, 4.0, 4.8, and 6.4 mm. The approximate value of currents to weld with 1.6, 3.2 and 6.4 mm diameter electrodes are 150–350, 250–800 and 650–1350 amps respectively.

  9. Reference electrode - Wikipedia

    en.wikipedia.org/wiki/Reference_electrode

    To focus on the reaction at the working electrode, the reference electrode is standardized with constant (buffered or saturated) concentrations of each participant of the redox reaction. [1] There are many ways reference electrodes are used. The simplest is when the reference electrode is used as a half-cell to build an electrochemical cell.