When.com Web Search

  1. Ad

    related to: auxiliary electrode for steel tube size chart

Search results

  1. Results From The WOW.Com Content Network
  2. Auxiliary electrode - Wikipedia

    en.wikipedia.org/wiki/Auxiliary_electrode

    The auxiliary electrode may be isolated from the working electrode using a glass frit. Such isolation prevents any byproducts generated at the auxiliary electrode from contaminating the main test solution: for example, if a reduction is being performed at the working electrode in aqueous solution, oxygen may be evolved from the auxiliary electrode.

  3. Nominal Pipe Size - Wikipedia

    en.wikipedia.org/wiki/Nominal_Pipe_Size

    Nominal Pipe Size (NPS) is a North American set of standard sizes for pipes used for high or low pressures and temperatures. [1] " Nominal" refers to pipe in non-specific terms and identifies the diameter of the hole with a non-dimensional number (for example – 2-inch nominal steel pipe" consists of many varieties of steel pipe with the only criterion being a 2.375-inch (60.3 mm) outside ...

  4. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    Both of these electrodes are balanced by a single reference and auxiliary combination for an overall four-electrode design. More complicated experiments may add working electrodes, reference, or auxiliary electrodes as required. [7] In practice it can be important to have a working electrode with known dimensions and surface characteristics.

  5. Reference electrode - Wikipedia

    en.wikipedia.org/wiki/Reference_electrode

    The connection can be direct, through a narrow tube to reduce mixing, or through a salt bridge, depending on the other electrode and solution. This creates an ionically conductive path to the working electrode of interest. A reference electrode is an electrode that has a stable and well-known electrode potential.

  6. Copper–copper (II) sulfate electrode - Wikipedia

    en.wikipedia.org/wiki/Copper–copper(II)_sulfate...

    The copper rod protrudes out of the tube. A voltmeter negative lead is connected to the copper rod. The potential of a copper–copper sulfate electrode is +0.314 volt with respect to the standard hydrogen electrode. [citation needed] Copper–copper(II) sulfate electrode is also used as one of the half cells in the galvanic Daniel-Jakobi cell.

  7. Galvanic series - Wikipedia

    en.wikipedia.org/wiki/Galvanic_series

    The difference can be measured as a difference in voltage potential: the less noble metal is the one with a lower (that is, more negative) electrode potential than the nobler one, and will function as the anode (electron or anion attractor) within the electrolyte device functioning as described above (a galvanic cell).

  8. Beam tetrode - Wikipedia

    en.wikipedia.org/wiki/Beam_tetrode

    An auxiliary electrode structure at or near cathode potential and substantially outside of the electron stream, to establish a low electrostatic potential region between the screen grid and anode, limit the included angle of the beam and prevent anode secondary electrons outside of the beam region from reaching the screen [10] [11] [8] (the ...

  9. Screen-printed electrodes - Wikipedia

    en.wikipedia.org/wiki/Screen-printed_electrodes

    It is the electrode that completes the circuit of the three-electrode cell, as it allows the passage of current. It enables the analysis of processes in which electronic transfer takes place. Screen-printed electrode with the three electrode system, reference electrode (RE), working electrode (WE) and auxiliary or counter electrode (AE or CE)