When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Foley catheter - Wikipedia

    en.wikipedia.org/wiki/Foley_catheter

    When a Foley catheter becomes clogged, it must be flushed or replaced. There is currently not enough adequate evidence to conclude whether washouts are beneficial or harmful. [13] There are several risks in using a Foley catheter (or catheters generally), including: The balloon can break as the healthcare provider inserts the catheter.

  3. Urinary catheterization - Wikipedia

    en.wikipedia.org/wiki/Urinary_catheterization

    Common indications for urinary catheterization include acute or chronic urinary retention (which can damage the kidneys) from conditions such as benign prostatic hyperplasia, orthopedic procedures that may limit a patient's movement, the need for accurate monitoring of input and output (such as in an ICU), urinary incontinence that may compromise the ability to heal wounds, and the effects of ...

  4. Frederic Foley - Wikipedia

    en.wikipedia.org/wiki/Frederic_Foley

    Diagram of a Foley catheter. Foley first described the use of a self-retaining balloon catheter in 1929, to be used to achieve hemostasis after cystoscopic prostatectomy. [2] He worked on development of this design for use as an indwelling urinary catheter, to provide continuous drainage of the bladder, in the 1930s.

  5. Mitrofanoff procedure - Wikipedia

    en.wikipedia.org/wiki/Mitrofanoff_procedure

    There are three major types of intermittent catheters used with a Mitrofanoff. [28] Intermittent catheters are used to drain the bladder at regular intervals. [28] The three types are: Non-coated: can be used with a lubricant [28] Hydrophilic: need to be activated with water by following the product instructions [28]

  6. Genitourinary tract injury - Wikipedia

    en.wikipedia.org/wiki/Genitourinary_tract_injury

    The tip of a small (12F) foley catheter is placed in the urethral meatus. [1] The catheter remains fixed after 3 mL of water are instilled into the foley catheter's balloon. [ 1 ] Radiographic films are taken as 20 mL of water-soluble contrast material are injected [ 1 ] This outlines the urethra from the urethral meatus to the bladder neck . [ 1 ]

  7. Catheter - Wikipedia

    en.wikipedia.org/wiki/Catheter

    Guiding catheters (catheters that guides angioplasty balloons and stents) is made up of polytetrafluoroethylene (PTFE) innermost layer which is lubricious, followed by stainless steel braid wire outer layer which helps to provide support for the catheter and prevent kinking while travelling through blood vessels, and Nylon elastomer outermost ...

  8. Retrograde urethrogram - Wikipedia

    en.wikipedia.org/wiki/Retrograde_urethrogram

    The subject lies down in a supine position. An 8 Fr Foley catheter is connected to a 50 ml syringe. The syringe is flushed to remove any air bubbles within the Foley catheter and the syringe. The tip of the catheter is then inserted into the urethra using aseptic technique until it is parked inside the navicular fossa.

  9. Intermittent catheterisation - Wikipedia

    en.wikipedia.org/wiki/Intermittent_catheterisation

    Intermittent catheters come in a variety of designs and differ depending on the user's genitals, with a catheter for a penis being longer and a catheter for a vulva being shorter. The catheter is inserted into the urethra by the patient or a carer and can either be directed down a toilet or, if measurement of volume is required, into a ...