Results From The WOW.Com Content Network
A typical motor start capacitor. A motor capacitor [1] [2] is an electrical capacitor that alters the current to one or more windings of a single-phase alternating-current induction motor to create a rotating magnetic field. [citation needed] There are two common types of motor capacitors, start capacitor and run capacitor (including a dual run ...
These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.
The capacitor-run designs keep the second winding on when running, improving torque. A resistance start design uses a starter inserted in series with the startup winding, creating reactance. Self-starting polyphase induction motors produce torque even at standstill.
A variation of the centrifugal switch used a changeover contact to ensure that the auxiliary windings remain in the circuit through a running capacitor. These motors are called two-value or capacitor start capacitor run motors. Centrifugal switches are found in many clothes dryers, supplying power to the motor in parallel with the start switch ...
Capacitor-run induction motors have a permanently connected phase-shifting capacitor in series with a second winding. The motor is much like a two-phase induction motor. Motor-starting capacitors are typically non-polarized electrolytic types, while running capacitors are conventional paper or plastic film dielectric types.
An HVAC component that uses outside air, under suitable climate conditions, to reduce required mechanical cooling. When the outside air’s enthalpy is less than the required supply air during a call for cooling, an economizer allows a building’s mechanical ventilation system to use up to the maximum amount of outside air.
Schematic of a capacitor start motor. A capacitor start motor is a split-phase induction motor with a starting motor capacitor inserted in series with the startup winding, creating an LC circuit which produces a greater phase shift (and so, a much greater starting torque) than both split-phase and shaded pole motors. This motor has a ...
A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the powertrain and electric current surge of the motor during start-up. This reduces the mechanical stress on the motor and shaft, as well as the electrodynamic stresses on the attached power cables and electrical distribution network ...