When.com Web Search

  1. Ad

    related to: hartford heating degree days calculation sheet sample

Search results

  1. Results From The WOW.Com Content Network
  2. Heating degree day - Wikipedia

    en.wikipedia.org/wiki/Heating_degree_day

    Heating degree day. Heating degree day (HDD) is a measurement designed to quantify the demand for energy needed to heat a building. HDD is derived from measurements of outside air temperature. The heating requirements for a given building at a specific location are considered to be directly proportional to the number of HDD at that location.

  3. Degree day - Wikipedia

    en.wikipedia.org/wiki/Degree_day

    A degree day is a measure of heating or cooling. Total degree days from an appropriate starting date are used to plan the planting of crops and management of pests and pest control timing. Weekly or monthly degree-day figures may also be used within an energy monitoring and targeting scheme to monitor the heating and cooling costs of climate ...

  4. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The equations for the use of the data retrieved from these tables are very simple. Q= heat gain, usually heat gain per unit time. A= surface area. U= Overall heat transfer coefficient. CLTD= cooling load temperature difference. SCL= solar cooling load factor. CLF= cooling load factor. SC= shading coefficient.

  5. US heating demand typically surpasses cooling demand after ...

    www.aol.com/news/us-heating-demand-typically...

    A heating degree day (HDD) is calculated by determining how many degrees the temperature drops below 65 °F. For example, a day with an average temperature of 50 °F is considered to have 15 HDDs.

  6. Balance point temperature - Wikipedia

    en.wikipedia.org/wiki/Balance_point_temperature

    The building balance point temperature is the outdoor air temperature when the heat gains of the building are equal to the heat losses. [1] Internal heat sources due to electric lighting, mechanical equipment, body heat, and solar radiation may offset the need for additional heating although the outdoor temperature may be below the thermostat set-point temperature.

  7. Proportional–integral–derivative controller - Wikipedia

    en.wikipedia.org/wiki/Proportional–integral...

    An asymmetric application, for example, is temperature control in HVAC systems using only active heating (via a heating element), where there is only passive cooling available. When it is desired to lower the controlled temperature the heating output is off, but there is no active cooling due to control output.

  8. How warm has this spring been? A look at degree-days in ... - AOL

    www.aol.com/warm-spring-look-degree-days...

    Across the state, there has been an annual reduction of 359 heating degree-days during 1958 to 2010 when compared data for 1895 to 1957, per EPA numbers. When comparing the same range of years ...

  9. Weather derivative - Wikipedia

    en.wikipedia.org/wiki/Weather_derivative

    Heating degree days are one of the most common index types for weather derivative evaluation. Typical terms for an HDD contract could be: for the November to March period, for each day when the daily mean temperature falls below a reference point (65 degrees Fahrenheit in the U.S., or, 18 degrees Celsius outside the U.S.), a cumulative count is ...